Intraoperative artificial intelligence system identifying liver vessels in laparoscopic liver resection: a retrospective experimental study.
Une, Norikazu; Kobayashi, Shin; Kitaguchi, Daichi; Sunakawa, Taiki; Sasaki, Kimimasa; Ogane, Tateo; Hayashi, Kazuyuki; Kosugi, Norihito; Kudo, Masashi; Sugimoto, Motokazu; Hasegawa, Hiro; Takeshita, Nobuyoshi; Gotohda, Naoto; Ito, Masaaki.
Afiliación
  • Une N; Department of Hepatobiliary and Pancreatic Surgery, National Cancer Center Hospital East, 6-5-1 Kashiwanoha, Kashiwa, Chiba, 277-8577, Japan.
  • Kobayashi S; Division of Medical Device Innovation, National Cancer Center Hospital East, 6-5-1 Kashiwanoha, Kashiwa, Chiba, 277-8577, Japan.
  • Kitaguchi D; Department of Hepatobiliary and Pancreatic Surgery, National Cancer Center Hospital East, 6-5-1 Kashiwanoha, Kashiwa, Chiba, 277-8577, Japan.
  • Sunakawa T; Division of Medical Device Innovation, National Cancer Center Hospital East, 6-5-1 Kashiwanoha, Kashiwa, Chiba, 277-8577, Japan.
  • Sasaki K; Department of Hepatobiliary and Pancreatic Surgery, National Cancer Center Hospital East, 6-5-1 Kashiwanoha, Kashiwa, Chiba, 277-8577, Japan.
  • Ogane T; Division of Medical Device Innovation, National Cancer Center Hospital East, 6-5-1 Kashiwanoha, Kashiwa, Chiba, 277-8577, Japan.
  • Hayashi K; Department of Hepatobiliary and Pancreatic Surgery, National Cancer Center Hospital East, 6-5-1 Kashiwanoha, Kashiwa, Chiba, 277-8577, Japan.
  • Kosugi N; Division of Medical Device Innovation, National Cancer Center Hospital East, 6-5-1 Kashiwanoha, Kashiwa, Chiba, 277-8577, Japan.
  • Kudo M; Division of Medical Device Innovation, National Cancer Center Hospital East, 6-5-1 Kashiwanoha, Kashiwa, Chiba, 277-8577, Japan.
  • Sugimoto M; Division of Medical Device Innovation, National Cancer Center Hospital East, 6-5-1 Kashiwanoha, Kashiwa, Chiba, 277-8577, Japan.
  • Hasegawa H; Division of Medical Device Innovation, National Cancer Center Hospital East, 6-5-1 Kashiwanoha, Kashiwa, Chiba, 277-8577, Japan.
  • Takeshita N; Department of Hepatobiliary and Pancreatic Surgery, National Cancer Center Hospital East, 6-5-1 Kashiwanoha, Kashiwa, Chiba, 277-8577, Japan.
  • Gotohda N; Department of Hepatobiliary and Pancreatic Surgery, National Cancer Center Hospital East, 6-5-1 Kashiwanoha, Kashiwa, Chiba, 277-8577, Japan.
  • Ito M; Division of Medical Device Innovation, National Cancer Center Hospital East, 6-5-1 Kashiwanoha, Kashiwa, Chiba, 277-8577, Japan.
Surg Endosc ; 38(2): 1088-1095, 2024 02.
Article en En | MEDLINE | ID: mdl-38216749
ABSTRACT

BACKGROUND:

The precise recognition of liver vessels during liver parenchymal dissection is the crucial technique for laparoscopic liver resection (LLR). This retrospective feasibility study aimed to develop artificial intelligence (AI) models to recognize liver vessels in LLR, and to evaluate their accuracy and real-time performance.

METHODS:

Images from LLR videos were extracted, and the hepatic veins and Glissonean pedicles were labeled separately. Two AI models were developed to recognize liver vessels the "2-class model" which recognized both hepatic veins and Glissonean pedicles as equivalent vessels and distinguished them from the background class, and the "3-class model" which recognized them all separately. The Feature Pyramid Network was used as a neural network architecture for both models in their semantic segmentation tasks. The models were evaluated using fivefold cross-validation tests, and the Dice coefficient (DC) was used as an evaluation metric. Ten gastroenterological surgeons also evaluated the models qualitatively through rubric.

RESULTS:

In total, 2421 frames from 48 video clips were extracted. The mean DC value of the 2-class model was 0.789, with a processing speed of 0.094 s. The mean DC values for the hepatic vein and the Glissonean pedicle in the 3-class model were 0.631 and 0.482, respectively. The average processing time for the 3-class model was 0.097 s. Qualitative evaluation by surgeons revealed that false-negative and false-positive ratings in the 2-class model averaged 4.40 and 3.46, respectively, on a five-point scale, while the false-negative, false-positive, and vessel differentiation ratings in the 3-class model averaged 4.36, 3.44, and 3.28, respectively, on a five-point scale.

CONCLUSION:

We successfully developed deep-learning models that recognize liver vessels in LLR with high accuracy and sufficient processing speed. These findings suggest the potential of a new real-time automated navigation system for LLR.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Inteligencia Artificial / Laparoscopía Tipo de estudio: Observational_studies / Prognostic_studies / Qualitative_research Límite: Humans Idioma: En Revista: Surg Endosc Asunto de la revista: DIAGNOSTICO POR IMAGEM / GASTROENTEROLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Inteligencia Artificial / Laparoscopía Tipo de estudio: Observational_studies / Prognostic_studies / Qualitative_research Límite: Humans Idioma: En Revista: Surg Endosc Asunto de la revista: DIAGNOSTICO POR IMAGEM / GASTROENTEROLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Japón