Your browser doesn't support javascript.
loading
An Initial Validation of Community-Based Air-Conduction Audiometry in Adults With Simulated Hearing Impairment Using a New Web App, DigiBel: Validation Study.
Sienko, Anna; Thirunavukarasu, Arun James; Kuzmich, Tanya; Allen, Louise.
Afiliación
  • Sienko A; School of Clinical Medicine, University of Cambridge, Cambridge, United Kingdom.
  • Thirunavukarasu AJ; Oxford University Clinical Academic Graduate School, University of Oxford, Oxford, United Kingdom.
  • Kuzmich T; School of Clinical Medicine, University of Cambridge, Cambridge, United Kingdom.
  • Allen L; Department of Ophthalmology, Cambridge University Hospitals NHS Foundation Trust, Cambridge, United Kingdom.
JMIR Form Res ; 8: e51770, 2024 Jan 25.
Article en En | MEDLINE | ID: mdl-38271088
ABSTRACT

BACKGROUND:

Approximately 80% of primary school children in the United States and Europe experience glue ear, which may impair hearing at a critical time for speech acquisition and social development. A web-based app, DigiBel, has been developed primarily to identify individuals with conductive hearing impairment who may benefit from the temporary use of bone-conduction assistive technology in the community.

OBJECTIVE:

This preliminary study aims to determine the screening accuracy and usability of DigiBel self-assessed air-conduction (AC) pure tone audiometry in adult volunteers with simulated hearing impairment prior to formal clinical validation.

METHODS:

Healthy adults, each with 1 ear plugged, underwent automated AC pure tone audiometry (reference test) and DigiBel audiometry in quiet community settings. Threshold measurements were compared across 6 tone frequencies and DigiBel test-retest reliability was calculated. The accuracy of DigiBel for detecting more than 20 dB of hearing impairment was assessed. A total of 30 adults (30 unplugged ears and 30 plugged ears) completed both audiometry tests.

RESULTS:

DigiBel had 100% sensitivity (95% CI 87.23-100) and 72.73% (95% CI 54.48-86.70) specificity in detecting hearing impairment. Threshold mean bias was insignificant except at 4000 and 8000 Hz where a small but significant overestimation of threshold measurement was identified. All 24 participants completing feedback rated the DigiBel test as good or excellent and 21 (88%) participants agreed or strongly agreed that they would be able to do the test at home without help.

CONCLUSIONS:

This study supports the potential use of DigiBel as a screening tool for hearing impairment. The findings will be used to improve the software further prior to undertaking a formal clinical trial of AC and bone-conduction audiometry in individuals with suspected conductive hearing impairment.
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Tipo de estudio: Prognostic_studies Idioma: En Revista: JMIR Form Res Año: 2024 Tipo del documento: Article País de afiliación: Reino Unido

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Tipo de estudio: Prognostic_studies Idioma: En Revista: JMIR Form Res Año: 2024 Tipo del documento: Article País de afiliación: Reino Unido