Your browser doesn't support javascript.
loading
Proceed with caution: Standard protocol exercise stress tests fail to replicate the diagnostic utility of supine-stand tests for long QT syndrome.
Pinsky, Alexa M; Kulkarni, Veda K; Bos, J Martijn; Neves, Raquel; Allison, Thomas G; Ackerman, Michael J.
Afiliación
  • Pinsky AM; Department of Cardiovascular Medicine (Division of Heart Rhythm Services), Windland Smith Rice Genetic Heart Rhythm Clinic, Mayo Clinic, Rochester, Minnesota, USA.
  • Kulkarni VK; Department of Cardiovascular Medicine (Division of Heart Rhythm Services), Windland Smith Rice Genetic Heart Rhythm Clinic, Mayo Clinic, Rochester, Minnesota, USA.
  • Bos JM; Department of Cardiovascular Medicine (Division of Heart Rhythm Services), Windland Smith Rice Genetic Heart Rhythm Clinic, Mayo Clinic, Rochester, Minnesota, USA.
  • Neves R; Department of Cardiovascular Medicine (Division of Heart Rhythm Services), Windland Smith Rice Genetic Heart Rhythm Clinic, Mayo Clinic, Rochester, Minnesota, USA.
  • Allison TG; Department of Cardiovascular Medicine (Division of Heart Rhythm Services), Windland Smith Rice Genetic Heart Rhythm Clinic, Mayo Clinic, Rochester, Minnesota, USA.
  • Ackerman MJ; Department of Cardiovascular Medicine (Division of Heart Rhythm Services), Windland Smith Rice Genetic Heart Rhythm Clinic, Mayo Clinic, Rochester, Minnesota, USA.
Pacing Clin Electrophysiol ; 47(3): 455-461, 2024 03.
Article en En | MEDLINE | ID: mdl-38348899
ABSTRACT

BACKGROUND:

Long QT syndrome (LQTS) is a sudden death predisposing condition characterized by ECG-derived prolongation of the QT interval. Previous studies have demonstrated that the supine-stand test may aid in the diagnosis of LQTS as patients fail to shorten their QT interval in response to standing up. The aim of this study was to evaluate the diagnostic accuracy of ECG data derived from standard protocol, clinically performed treadmill exercise stress tests (TESTs) in their ability to mimic the formal supine-stand test.

METHODS:

We performed a retrospective review of 478 TESTs from patients evaluated for LQTS. Patients referred for evaluation of LQTS but who were dismissed as normal served as controls. Heart rate & QT values were obtained from standard protocol TESTs.

RESULTS:

Overall, 243 patients with LQTS (125 LQT1, 63 LQT2, 55 LQT3; 146 [60%] female, mean age at TEST 30 ± 17 years) and 235 controls (142 [60%] female, mean age 24 ± 15 years) were included. The paired ΔQTc (QTcStand -QTcSupine ) was similar between LQTS (-5 ± 26) and controls (-2 ± 25; p = .2). During position change, the QT interval shortened by ≥20 ms in 33% of LQTS patients, remained unchanged in 62%, and increased in 5% of LQTS patients which was similar to controls (shortened in 40%, unchanged in 54%, and increased in 6% of controls; p = .2). Receiver-operator curve analysis to test the diagnostic ability of supine-stand ΔQT performed poorly in differentiating LQTS from controls with an of AUC 0.52 (p = .4).

CONCLUSION:

TESTs should be used with caution when trying to interpret supine-stand changes for diagnosis of LQTS.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Síndrome de QT Prolongado / Prueba de Esfuerzo Tipo de estudio: Diagnostic_studies / Guideline Límite: Adolescent / Adult / Child / Female / Humans / Male Idioma: En Revista: Pacing Clin Electrophysiol Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Síndrome de QT Prolongado / Prueba de Esfuerzo Tipo de estudio: Diagnostic_studies / Guideline Límite: Adolescent / Adult / Child / Female / Humans / Male Idioma: En Revista: Pacing Clin Electrophysiol Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos