Your browser doesn't support javascript.
loading
Dynamic recurrent inference machines for accelerated MRI-guided radiotherapy of the liver.
Lønning, Kai; Caan, Matthan W A; Nowee, Marlies E; Sonke, Jan-Jakob.
Afiliación
  • Lønning K; Netherlands Cancer Institute, Department of Radiotherapy, Plesmanlaan 121, 1066 CX Amsterdam, The Netherlands; Spinoza Centre for Neuroimaging, Meibergdreef 75, 1105 BK Amsterdam, The Netherlands.
  • Caan MWA; Amsterdam UMC location University of Amsterdam, Department of Biomedical Engineering and Physics, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands.
  • Nowee ME; Netherlands Cancer Institute, Department of Radiotherapy, Plesmanlaan 121, 1066 CX Amsterdam, The Netherlands.
  • Sonke JJ; Netherlands Cancer Institute, Department of Radiotherapy, Plesmanlaan 121, 1066 CX Amsterdam, The Netherlands. Electronic address: j.sonke@nki.nl.
Comput Med Imaging Graph ; 113: 102348, 2024 04.
Article en En | MEDLINE | ID: mdl-38368665
ABSTRACT
Recurrent inference machines (RIM), a deep learning model that learns an iterative scheme for reconstructing sparsely sampled MRI, has been shown able to perform well on accelerated 2D and 3D MRI scans, learn from small datasets and generalize well to unseen types of data. Here we propose the dynamic recurrent inference machine (DRIM) for reconstructing sparsely sampled 4D MRI by exploiting correlations between respiratory states. The DRIM was applied to a 4D protocol for MR-guided radiotherapy of liver lesions based on repetitive interleaved coronal 2D multi-slice T2-weighted acquisitions. We demonstrate with an ablation study that the DRIM outperforms the RIM, increasing the SSIM score from about 0.89 to 0.95. The DRIM allowed for an approximately 2.7 times faster scan time than the current clinical protocol with only a slight loss in image sharpness. Correlations between slice locations can also be used, but were found to be of less importance, as were a majority of tested variations in network architecture, as long as the respiratory states are processed by the network. Through cross-validation, the DRIM is also shown to be robust in terms of training data. We further demonstrate a good performance across a large range of subsampling factors, and conclude through an evaluation by a radiation oncologist that reconstructed images of the liver contour and inner structures are of a clinically acceptable standard at acceleration factors 10x and 8x, respectively. Finally, we show that binning the data with respect to respiratory states prior to reconstruction comes at a slight cost to reconstruction quality, but at greater speed of the overall protocol.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Hígado Idioma: En Revista: Comput Med Imaging Graph Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2024 Tipo del documento: Article País de afiliación: Países Bajos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Hígado Idioma: En Revista: Comput Med Imaging Graph Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2024 Tipo del documento: Article País de afiliación: Países Bajos