Your browser doesn't support javascript.
loading
First Acyclovir Determination Procedure via Electrochemically Activated Screen-Printed Carbon Electrode Coupled with Well-Conductive Base Electrolyte.
Tyszczuk-Rotko, Katarzyna; Staniec, Katarzyna; Gorylewski, Damian; Keller, Aleksy.
Afiliación
  • Tyszczuk-Rotko K; Institute of Chemical Sciences, Faculty of Chemistry, Maria Curie-Sklodowska University, 20-031 Lublin, Poland.
  • Staniec K; Institute of Chemical Sciences, Faculty of Chemistry, Maria Curie-Sklodowska University, 20-031 Lublin, Poland.
  • Gorylewski D; Institute of Chemical Sciences, Faculty of Chemistry, Maria Curie-Sklodowska University, 20-031 Lublin, Poland.
  • Keller A; Institute of Chemical Sciences, Faculty of Chemistry, Maria Curie-Sklodowska University, 20-031 Lublin, Poland.
Sensors (Basel) ; 24(4)2024 Feb 08.
Article en En | MEDLINE | ID: mdl-38400283
ABSTRACT
In this work, a new voltammetric procedure for acyclovir (ACY) trace-level determination has been described. For this purpose, an electrochemically activated screen-printed carbon electrode (aSPCE) coupled with well-conductive electrolyte (CH3COONH4, CH3COOH and NH4Cl) was used for the first time. A commercially available SPCE sensor was electrochemically activated by conducting cyclic voltammetry (CV) scans in 0.1 mol L-1 NaOH solution and rinsed with deionized water before a series of measurements were taken. This treatment reduced the charge transfer resistance, increased the electrode active surface area and improved the kinetics of the electron transfer. The activation step and high conductivity of supporting electrolyte significantly improved the sensitivity of the procedure. The newly developed differential-pulse adsorptive stripping voltammetry (DPAdSV) procedure is characterized by having the lowest limit of detection among all voltammetric procedures currently described in the literature (0.12 nmol L-1), a wide linear range of the calibration curve (0.5-50.0 and 50.0-1000.0 nmol L-1) as well as extremely high sensitivity (90.24 nA nmol L-1) and was successfully applied in the determination of acyclovir in commercially available pharmaceuticals.
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Sensors (Basel) Año: 2024 Tipo del documento: Article País de afiliación: Polonia

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Sensors (Basel) Año: 2024 Tipo del documento: Article País de afiliación: Polonia