Right disc thrombosis of the new Gore Cardioform ASD Occluder.
Oliva, Omar A; Giugno, Luca; Moroni, Alice; Sturla, Francesco; Piazza, Luciane; Saracino, Antonio; Micheletti, Angelo; d'Aiello, Angelo Fabio; Reali, Matteo; Chessa, Massimo; Carminati, Mario.
Afiliación
  • Oliva OA; Pediatric and Adult Congenital Heart Center, IRCCS Policlinico San Donato, San Donato Milanese, Italy.
  • Giugno L; Pediatric and Adult Congenital Heart Center, IRCCS Policlinico San Donato, San Donato Milanese, Italy.
  • Moroni A; Pediatric and Adult Congenital Heart Center, IRCCS Policlinico San Donato, San Donato Milanese, Italy.
  • Sturla F; 3D and Computer Simulation Laboratory, IRCCS Policlinico San Donato, San Donato Milanese, Italy.
  • Piazza L; Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano, Italy.
  • Saracino A; Pediatric and Adult Congenital Heart Center, IRCCS Policlinico San Donato, San Donato Milanese, Italy.
  • Micheletti A; Pediatric and Adult Congenital Heart Center, IRCCS Policlinico San Donato, San Donato Milanese, Italy.
  • d'Aiello AF; ACHD Unit - Pediatric and Adult Congenital Heart Center, IRCCS Policlinico San Donato, San Donato Milanese, Italy.
  • Reali M; ACHD Unit - Pediatric and Adult Congenital Heart Center, IRCCS Policlinico San Donato, San Donato Milanese, Italy.
  • Chessa M; Congenital Cardiac Surgery Unit, IRCCS-Policlinico San Donato, San Donato Milanese, Italy.
  • Carminati M; ACHD Unit - Pediatric and Adult Congenital Heart Center, IRCCS Policlinico San Donato, San Donato Milanese, Italy.
Catheter Cardiovasc Interv ; 103(5): 741-750, 2024 Apr.
Article en En | MEDLINE | ID: mdl-38451154
ABSTRACT

BACKGROUND:

The GCA is a well performing device in terms of efficacy despite complex anatomies (aortic rim <5 mm and ASD diameter >17 mm) with a good safety profile.

AIMS:

To evaluate atrial septal defect (ASD) features impacting on right disc device thrombosis in patients who underwent Gore Cardioform ASD Occluder (GCA) implantation.

METHODS:

A total of 44 consecutive patients undergoing percutaneous ASD with GCA device from January 2020 to September 2022 at our tertiary care Center were evaluated. The minimum follow-up was 6 months.

RESULTS:

The patients were stratified in two groups according to a cut-off value of ASD diameter equal to 20 mm at sizing balloon, derived from ROC analysis (AUC = 0.894; p = 0.024). Baseline characteristics were comparable between groups in terms of age, sex, weight, height, and interatrial septum dimensions. Patients with ASD > 20 mm (n = 9) had a higher ASD/device dimension ratio, both at echocardiography (p = 0.009) and at sizing balloon (p = 0.001), longer fluoroscopic time (p = 0.022), and higher incidence of device thrombosis (0.006). Right disc thrombosis was observed in three patients of the ASD > 20 mm group, always in the inferior portion of the right disc. On univariate analysis, ASD diameter at sizing balloon (OR 1.360; p = 0.036) was the only positive predictor of device thrombosis.

CONCLUSIONS:

Right disc thrombosis of the GCA device may be under-recognized at follow-up, hence deserving clinical attention, especially in those patients with larger ASD diameters.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Dispositivo Oclusor Septal / Defectos del Tabique Interatrial Límite: Humans Idioma: En Revista: Catheter Cardiovasc Interv Asunto de la revista: CARDIOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Italia

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Dispositivo Oclusor Septal / Defectos del Tabique Interatrial Límite: Humans Idioma: En Revista: Catheter Cardiovasc Interv Asunto de la revista: CARDIOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Italia