Your browser doesn't support javascript.
loading
Design of Experimental Approach for Development of Rapid High Performance Liquid Chromatographic Process for Simultaneous Estimation of Metoprolol, Telmisartan, and Amlodipine from Formulation: Greenness and Whiteness Evaluation.
Attimarad, Mahesh; Alali, Mohammed Jassim; Alali, Hussain Ali; Alabdulmuhsin, Dana Hisham; Alnajdi, Aljohara Khalid; Venugopala, Katharigatta Narayanaswamy; Nair, Anroop B.
Afiliación
  • Attimarad M; Department of Pharmaceutical Sciences, College of Clinical Pharmacy, King Faisal University, Al-Ahsa 31982, Saudi Arabia.
  • Alali MJ; Department of Pharmaceutical Sciences, College of Clinical Pharmacy, King Faisal University, Al-Ahsa 31982, Saudi Arabia.
  • Alali HA; Department of Pharmaceutical Sciences, College of Clinical Pharmacy, King Faisal University, Al-Ahsa 31982, Saudi Arabia.
  • Alabdulmuhsin DH; Department of Pharmaceutical Sciences, College of Clinical Pharmacy, King Faisal University, Al-Ahsa 31982, Saudi Arabia.
  • Alnajdi AK; Department of Pharmaceutical Sciences, College of Clinical Pharmacy, King Faisal University, Al-Ahsa 31982, Saudi Arabia.
  • Venugopala KN; Department of Pharmaceutical Sciences, College of Clinical Pharmacy, King Faisal University, Al-Ahsa 31982, Saudi Arabia.
  • Nair AB; Department of Biotechnology and Food Science, Faculty of Applied Sciences, Durban University of Technology, Durban 4001, South Africa.
Molecules ; 29(5)2024 Feb 29.
Article en En | MEDLINE | ID: mdl-38474605
ABSTRACT
The design of an experimental approach, the Box-Behnken design, was implemented to optimize the chromatographic condition to develop a rapid HPLC procedure for quantification of a ternary mixture of metoprolol (MET), telmisartan (TEL), and amlodipine (AML) from the formulation. The perturbation plots, contour, and 3D response surface pictures were developed to study the impact of each variable on the analytes' retention time and the probable interaction between the parameters with fewer chromatographic runs. The optimized HPLC method separated the three analytes within 5 min with excellent selectivity and peak shape on a Zorbax C18 HPLC column using acetonitrile and phosphate buffer (20 mM, pH 5.8) with isocratic elution at a 1.1 mL/min flowrate. A wavelength 230 nm was utilized to monitor the elute. The validation of proposed method demonstrated a wide linearity range of 10-200 µg/mL for MET and TEL and 5-50 µg/mL for AML along with an excellent correlation coefficient. The correctness of the HPLC approach was further confirmed by excellent recovery of the added amount of analytes utilizing the standard addition technique. The recommended HPLC approach was employed safely for quality assurance of the formulation, because the evaluation of the method's greenness and whiteness confirmed the environmentally friendly nature of the approach.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Leucemia Mieloide Aguda / Amlodipino Límite: Humans Idioma: En Revista: Molecules Asunto de la revista: BIOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Arabia Saudita

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Leucemia Mieloide Aguda / Amlodipino Límite: Humans Idioma: En Revista: Molecules Asunto de la revista: BIOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Arabia Saudita