Your browser doesn't support javascript.
loading
Development of an easy-to-set-up multiple heart-cutting achiral-chiral LC-LC method for the analysis of branched-chain amino acids in commercial tablets.
Varfaj, Ina; Abualzulof, Ghaid W A; Moretti, Simone; Migni, Anna; Uda, Irene; Goracci, Laura; Ianni, Federica; Carotti, Andrea; Sardella, Roccaldo.
Afiliación
  • Varfaj I; Department of Pharmaceutical Sciences, University of Perugia, Perugia, Italy.
  • Abualzulof GWA; Department of Pharmaceutical Sciences, University of Perugia, Perugia, Italy.
  • Moretti S; Molecular Horizon, Bettona, Perugia, Italy.
  • Migni A; Department of Pharmaceutical Sciences, University of Perugia, Perugia, Italy.
  • Uda I; Department of Pharmaceutical Sciences, University of Perugia, Perugia, Italy.
  • Goracci L; Department of Chemistry, Biology and Biotechnology, University of Perugia, Perugia, Italy.
  • Ianni F; Department of Pharmaceutical Sciences, University of Perugia, Perugia, Italy.
  • Carotti A; Department of Pharmaceutical Sciences, University of Perugia, Perugia, Italy.
  • Sardella R; Department of Pharmaceutical Sciences, University of Perugia, Perugia, Italy.
Electrophoresis ; 45(11-12): 1041-1053, 2024 Jun.
Article en En | MEDLINE | ID: mdl-38477690
ABSTRACT
In this paper, the development and application of a multiple heart-cutting achiral-chiral LC-LC method (mLC-LC) for the analysis of dansylated (Dns) branched-chain amino acids in commercial tablets are described. In the first dimension, a Waters Xbridge RP C18 achiral column was used under gradient conditions with buffered aqueous solution and acetonitrile. The elution order Dns-valine (Dns-Val) < Dns-isoleucine (Dns-Ile) < Dns-leucine (Dns-Leu) turned out with full resolution between adjacent peaks 7.25 and 1.50 for the Val/Ile and the Ile/Leu pairs, respectively. A "research" validation study was performed, revealing high accuracy (Recovery%) and precision (RSD%) using two external set solutions, respectively, in the range 93.7%-104.1% and 0.4%-3.2%. The C18 column was connected via a two-position six-port switching valve to the quinidine-based Chiralpak quinidine-anion-exchange chiral column. A water/acetonitrile, 30/70 (v/v) with 50 mM ammonium acetate (apparent pH of 5.5) eluent allowed getting the three enantiomers' pairs resolved RS equal to 4.3 for Dns-Val and Dns-Ile, and 1.7 for Dns-Leu. The application of the mLC-LC method confirmed that the content of Val, Ile, and Leu in the tablets was compliant with that labeled by the producer. Only l-enantiomers were found in the food supplement, as confirmed by LC-MS/MS analysis.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Comprimidos / Aminoácidos de Cadena Ramificada Idioma: En Revista: Electrophoresis Año: 2024 Tipo del documento: Article País de afiliación: Italia

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Comprimidos / Aminoácidos de Cadena Ramificada Idioma: En Revista: Electrophoresis Año: 2024 Tipo del documento: Article País de afiliación: Italia