Your browser doesn't support javascript.
loading
Relationship between pectoralis major stiffness and shoulder extension range of motion.
Konrad, Andreas; Reiner, Marina M; Warneke, Konstantin; Keiner, Michael; Nakamura, Masatoshi; Tilp, Markus.
Afiliación
  • Konrad A; Institute of Human Movement Science, Sport and Health, Graz University, Graz, Austria.
  • Reiner MM; Institute of Human Movement Science, Sport and Health, Graz University, Graz, Austria.
  • Warneke K; Institute of Sport Science, University of Klagenfurt, Klagenfurt, Austria.
  • Keiner M; Department of Exercise Science, German University of Health and Sport, Ismaning, Germany.
  • Nakamura M; Faculty of Rehabilitation Sciences, Nishi Kyushu University, Saga, Japan.
  • Tilp M; Institute of Human Movement Science, Sport and Health, Graz University, Graz, Austria.
Front Physiol ; 15: 1349426, 2024.
Article en En | MEDLINE | ID: mdl-38510941
ABSTRACT
This study aimed to investigate the correlation between the passive muscle stiffness of the pectoralis major muscle pars clavicularis (PMc) and shoulder extension range of motion (ROM) in both male and female participants. Thirty-nine (23 male/16 female) physically active and healthy participants volunteered in this study. After a standardized warm-up, the PMc stiffness was tested via shear wave elastography at a slightly stretched position (long muscle length) and in a non-stretched position (short muscle length). Additionally, a custom-made device and 3D motion capture assessed the active shoulder extension ROM. We found a significant moderate and negative relationship between shoulder extension ROM and PMc stiffness at long muscle length (rs = -0.33; p = 0.04) but not at short muscle length (r = -0.23; p = 0.17). Additionally, there was no significant difference between male and female participants in the correlation analyses at both elbow angles. The moderate correlation between PMc stiffness at a slightly stretched position and shoulder extension ROM suggests that additionally, other structures such as nerves/fascia stiffness or even stretch tolerance might be factors that can be related to shoulder extension ROM.
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Front Physiol Año: 2024 Tipo del documento: Article País de afiliación: Austria

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Front Physiol Año: 2024 Tipo del documento: Article País de afiliación: Austria