Factors associated with the disinfection of devices attached to peripheral intravenous catheters performed by the nursing team in pediatric units.
Silva, Thiago Lopes; Dos Santos, Luciano Marques; Kusahara, Denise Miyuki; Burciaga, Luz Verónica Berumen; Biazus Dalcin, Camila; de Souza, Sabrina; Bitencourt, Aline de Souza; Rocha, Patrícia Kuerten.
Afiliación
  • Silva TL; Postgraduate Program in Nursing, Nursing Department, Health Sciences Centre, Universidade Federal de Santa Catarina, Florianopolis, Brazil.
  • Dos Santos LM; Postgraduate Program in Nursing, Health Department, Universidade Estadual de Feira de Santana, Feira de Santana, Brazil.
  • Kusahara DM; Postgraduate Program in Nursing, Sao Paulo School of Nursing, Universidade Federal de São Paulo, Sao Paulo, Brazil.
  • Burciaga LVB; Faculty of Nursing and Nutriology, Universidad Autónoma de Chihuahua, Chihuahua, Mexico.
  • Biazus Dalcin C; School of Health Sciences, University of Dundee, Dundee, Scotland.
  • de Souza S; Postgraduate Program in Nursing, Nursing Department, Health Sciences Centre, Universidade Federal de Santa Catarina, Florianopolis, Brazil.
  • Bitencourt AS; Postgraduate Program in Nursing, Nursing Department, Health Sciences Centre, Universidade Federal de Santa Catarina, Florianopolis, Brazil.
  • Rocha PK; Postgraduate Program in Nursing, Nursing Department, Health Sciences Centre, Universidade Federal de Santa Catarina, Florianopolis, Brazil.
J Infect Prev ; 25(3): 66-72, 2024 May.
Article en En | MEDLINE | ID: mdl-38584710
ABSTRACT

Background:

Peripheral intravenous catheterization, as well as drug administration through it, represents one of the most performed procedures by the Nursing team and, for that, precautions need to be adopted to offer harm-free care.

Objective:

To verify the association of Nursing professionals' work shift and training time with proper disinfection of intravenous catheter devices in pediatric units.

Methods:

A cross-sectional and analytical study conducted between June and August 2021 in three hospitalization units of a Pediatric Hospital. The inclusion criterion was drug administration via peripheral intravenous catheters performed by Nursing professionals. The data were analyzed according to inferential statistics, adopting p ≤ .05 as significance level.

Results:

There were a total of 385 observations of drug administration procedures. The device was not disinfected in 60.3% of the cases, there was no friction at the suitable time in 86.3%, and the disinfectant was not allowed to dry in 72.5%. The work shift exerted no influence on performance of the disinfection procedure (p = .376). However, longer training time was associated with a lower rate in performing such procedure (p < .001).

Conclusion:

Performing friction below the recommended time can cause a false sense of prevention of catheter-associated bloodstream infection; therefore, training sessions and strategies for adherence to the disinfection procedures should be considered, mainly for professionals with more training time.