Your browser doesn't support javascript.
loading
Distortionless, free-breathing, and respiratory resolved 3D diffusion weighted imaging of the abdomen.
Lee, Philip K; Zhou, Xuetong; Wang, Nan; Syed, Ali B; Brunsing, Ryan L; Vasanawala, Shreyas S; Hargreaves, Brian A.
Afiliación
  • Lee PK; Radiology, Stanford University, Stanford, California, USA.
  • Zhou X; Radiology, Stanford University, Stanford, California, USA.
  • Wang N; Bioengineering, Stanford University, Stanford, California, USA.
  • Syed AB; Radiology, Stanford University, Stanford, California, USA.
  • Brunsing RL; Radiology, Stanford University, Stanford, California, USA.
  • Vasanawala SS; Radiology, Stanford University, Stanford, California, USA.
  • Hargreaves BA; Radiology, Stanford University, Stanford, California, USA.
Magn Reson Med ; 92(2): 586-604, 2024 Aug.
Article en En | MEDLINE | ID: mdl-38688875
ABSTRACT

PURPOSE:

Abdominal imaging is frequently performed with breath holds or respiratory triggering to reduce the effects of respiratory motion. Diffusion weighted sequences provide a useful clinical contrast but have prolonged scan times due to low signal-to-noise ratio (SNR), and cannot be completed in a single breath hold. Echo-planar imaging (EPI) is the most commonly used trajectory for diffusion weighted imaging but it is susceptible to off-resonance artifacts. A respiratory resolved, three-dimensional (3D) diffusion prepared sequence that obtains distortionless diffusion weighted images during free-breathing is presented. Techniques to address the myriad of challenges including 3D shot-to-shot phase correction, respiratory binning, diffusion encoding during free-breathing, and robustness to off-resonance are described.

METHODS:

A twice-refocused, M1-nulled diffusion preparation was combined with an RF-spoiled gradient echo readout and respiratory resolved reconstruction to obtain free-breathing diffusion weighted images in the abdomen. Cartesian sampling permits a sampling density that enables 3D shot-to-shot phase navigation and reduction of transient fat artifacts. Theoretical properties of a region-based shot rejection are described. The region-based shot rejection method was evaluated with free-breathing (normal and exaggerated breathing), and respiratory triggering. The proposed sequence was compared in vivo with multishot DW-EPI.

RESULTS:

The proposed sequence exhibits no evident distortion in vivo when compared to multishot DW-EPI, robustness to B0 and B1 field inhomogeneities, and robustness to motion from different respiratory patterns.

CONCLUSION:

Acquisition of distortionless, diffusion weighted images is feasible during free-breathing with a b-value of 500 s/mm2, scan time of 6 min, and a clinically viable reconstruction time.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Artefactos / Imagenología Tridimensional / Imagen de Difusión por Resonancia Magnética / Abdomen Límite: Humans Idioma: En Revista: Magn Reson Med Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Artefactos / Imagenología Tridimensional / Imagen de Difusión por Resonancia Magnética / Abdomen Límite: Humans Idioma: En Revista: Magn Reson Med Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos