Your browser doesn't support javascript.
loading
Selective Angiographic Evaluation in Patients with Simple-Type Pulmonary Arteriovenous Malformations Treated with Vascular Plug.
Wada, Shinji; Hamaguchi, Shingo; Hashimoto, Kazuki; Nawata, Shintaro; Matsuoka, Shin; Mimura, Hidefumi.
Afiliación
  • Wada S; Department of Diagnostic and Interventional Radiology, St. Marianna University School of Medicine, 2-16-1, Sugao, Miyamae-ku, Kawasaki City, Kanagawa, 216-8511, Japan. shinjiwada@marianna-u.ac.jp.
  • Hamaguchi S; Department of Diagnostic and Interventional Radiology, St. Marianna University School of Medicine, 2-16-1, Sugao, Miyamae-ku, Kawasaki City, Kanagawa, 216-8511, Japan.
  • Hashimoto K; Department of Diagnostic and Interventional Radiology, St. Marianna University School of Medicine, 2-16-1, Sugao, Miyamae-ku, Kawasaki City, Kanagawa, 216-8511, Japan.
  • Nawata S; Department of Diagnostic and Interventional Radiology, St. Marianna University School of Medicine, 2-16-1, Sugao, Miyamae-ku, Kawasaki City, Kanagawa, 216-8511, Japan.
  • Matsuoka S; Department of Diagnostic and Interventional Radiology, St. Marianna University School of Medicine, 2-16-1, Sugao, Miyamae-ku, Kawasaki City, Kanagawa, 216-8511, Japan.
  • Mimura H; Department of Diagnostic and Interventional Radiology, St. Marianna University School of Medicine, 2-16-1, Sugao, Miyamae-ku, Kawasaki City, Kanagawa, 216-8511, Japan.
Cardiovasc Intervent Radiol ; 47(8): 1101-1108, 2024 Aug.
Article en En | MEDLINE | ID: mdl-38898148
ABSTRACT

PURPOSE:

To evaluate the angiographic recanalization rate of patients who underwent embolization juxta-proximal to the sac with AMPLATZER Vascular Plug type IV (AVP IV) for a simple pulmonary arteriovenous malformation (PAVM). MATERIAL AND

METHODS:

Ten patients (7 females and 3 males; median age, 47 years [range 28-83 years]) with 19 simple-type PAVMs who underwent embolization using an AVP IV between May 2015 and November 2021 were included in this retrospective study. The median feeding artery diameter on computed tomography was 4.0 mm (range 3-5.9 mm), and the median ratio of AVP IV size to feeding artery diameter on computed tomography was 1.5 (range 1.3-2.1). Technical success was defined by AVP IV placement at the junction between the pulmonary artery and the sac, or the pulmonary artery within 1 cm from the junction and beyond the last normal branch. The primary endpoint was the PAVM recanalization rate in selective or segmental pulmonary angiography performed 1 year post-embolization.

RESULTS:

The technical success rate of embolization juxta-proximal to the sac for simple-type PAVMs was 100%. None of the 19 lesions showed recanalization in pulmonary angiography performed 1 year after embolization. One patient experienced hemoptysis and pneumonia.

CONCLUSION:

Embolization of simple-type PAVMs' feeding vessel using AVP IV is safe and effective, with a high technical success rate and no recanalization on pulmonary angiography performed at 1 year post-embolization.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Malformaciones Arteriovenosas / Arteria Pulmonar / Venas Pulmonares / Embolización Terapéutica Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Cardiovasc Intervent Radiol Año: 2024 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Malformaciones Arteriovenosas / Arteria Pulmonar / Venas Pulmonares / Embolización Terapéutica Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Cardiovasc Intervent Radiol Año: 2024 Tipo del documento: Article País de afiliación: Japón