Your browser doesn't support javascript.
loading
Proving the automatic benchtop electrochemical station for the development of dopamine and paracetamol sensors.
Hasso, Marek; Kudr, Jirí; Zítka, Jan; Sílený, Jan; Svec, Pavel; Svorc, Lubomír; Zítka, Ondrej.
Afiliación
  • Hasso M; Institute of Analytical Chemistry, Faculty of Chemical and Food Technology, Slovak University of Technology in Bratislava, Radlinského 9, Bratislava, 812 37, Slovakia.
  • Kudr J; Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, Brno, 613 00, Czech Republic.
  • Zítka J; Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, Brno, 613 00, Czech Republic.
  • Sílený J; Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, Brno, 613 00, Czech Republic.
  • Svec P; Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, Brno, 613 00, Czech Republic.
  • Svorc L; Institute of Analytical Chemistry, Faculty of Chemical and Food Technology, Slovak University of Technology in Bratislava, Radlinského 9, Bratislava, 812 37, Slovakia.
  • Zítka O; Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, Brno, 613 00, Czech Republic. zitkao@seznam.cz.
Mikrochim Acta ; 191(7): 408, 2024 06 20.
Article en En | MEDLINE | ID: mdl-38898321
ABSTRACT
The introduced work represents an implementation of the automatic benchtop electrochemical station (BES) as an effective tool for the possibilities of high-throughput preparation of modified sensor/biosensors, speeding up the development of the analytical method, and automation of the analytical procedure for the determination of paracetamol (PAR) and dopamine (DOP) as target analytes. Within the preparation of gold nanoparticles modified screen-printed carbon electrode (AuNPs-SPCE) by electrodeposition, the deposition potential EDEP, the deposition time tDEP, and the concentration of HAuCl4 were optimized and their influence was monitored on 1 mM [Ru(NH3)6]3+/2+ redox probe and 50 µM DOP. The morphology of the AuNPs-SPCE prepared at various modification conditions was observed by SEM. The analytical performance of the AuNPs-SPCE prepared at different modification conditions was evaluated by a construction of the calibration curves of DOP and PAR. SPCE and AuNPs-SPCE at modification condition providing the best sensitivity to PAR and DOP, were successfully used to determine PAR and DOP in tap water by "spike-recovery" approach. The BES yields better reproducibility of the preparation of AuNPs-SPCE (RSD = 3.0%) in comparison with the case when AuNPs-SPCE was prepared manually by highly skilled laboratory operator (RSD = 7.0%).
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Dopamina / Nanopartículas del Metal / Técnicas Electroquímicas / Oro / Acetaminofén Idioma: En Revista: Mikrochim Acta Año: 2024 Tipo del documento: Article País de afiliación: Eslovaquia

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Dopamina / Nanopartículas del Metal / Técnicas Electroquímicas / Oro / Acetaminofén Idioma: En Revista: Mikrochim Acta Año: 2024 Tipo del documento: Article País de afiliación: Eslovaquia