Your browser doesn't support javascript.
loading
Construction of composite self-assembly coating based on chitosan for enhancing the flame-retardant and antibacterial performances of cotton fabric.
Wang, Yaxuan; Ren, Jinyong; Ou, Mingyu; Piao, Junxiu; Lian, Richeng; Cui, Jiahui; Guan, Haocun; Jiao, Chuanmei; Chen, Xilei.
Afiliación
  • Wang Y; College of Environment and Safety Engineering, Qingdao University of Science and Technology, Qingdao, Shandong 266042, PR China.
  • Ren J; College of Environment and Safety Engineering, Qingdao University of Science and Technology, Qingdao, Shandong 266042, PR China.
  • Ou M; College of Environment and Safety Engineering, Qingdao University of Science and Technology, Qingdao, Shandong 266042, PR China.
  • Piao J; College of Environment and Safety Engineering, Qingdao University of Science and Technology, Qingdao, Shandong 266042, PR China.
  • Lian R; College of Environment and Safety Engineering, Qingdao University of Science and Technology, Qingdao, Shandong 266042, PR China.
  • Cui J; College of Environment and Safety Engineering, Qingdao University of Science and Technology, Qingdao, Shandong 266042, PR China.
  • Guan H; College of Environment and Safety Engineering, Qingdao University of Science and Technology, Qingdao, Shandong 266042, PR China.
  • Jiao C; College of Environment and Safety Engineering, Qingdao University of Science and Technology, Qingdao, Shandong 266042, PR China. Electronic address: jiaochm@qust.edu.cn.
  • Chen X; College of Environment and Safety Engineering, Qingdao University of Science and Technology, Qingdao, Shandong 266042, PR China. Electronic address: xilei_chen@foxmail.com.
Int J Biol Macromol ; 275(Pt 2): 133355, 2024 Aug.
Article en En | MEDLINE | ID: mdl-38945711
ABSTRACT
In this work, the step-by-step dip-coating (SBS) method was used to effectively improve the drawback of LBL by reducing the construction of a multilayer polyelectrolyte. Bio-based flame retardants, phytic acid (PA), and chitosan (CS) were further self-assembly on the surface of cotton fabric treated by epichlorohydrin-modified aramid nanofibers (AEP), ionic liquid (IL), and Cu ion. The pure cotton fabric was immersed in each dipping liquid only once, improving fire safety and antibacterial performance. The treated cotton self-extinguished with a 59 mm char length in the vertical flammability test, and the limiting oxygen index (LOI) value increased from 18.5 % to 38.5 %. The result of the cone calorimeter test (CCT) revealed that the fire hazard of flame-retardant cotton noteworthy declined (e.g., ~44.1 % and 55.4 % decline in peak heat release rate (pHRR) and total heat release rate (THR)). Conspicuously, the treated cotton exhibited a remarkably inhibiting effect on E. coli and S. aureus activity. The cotton fabric after flame-retardant finishing exhibited excellent fire safety and antibacterial performance.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Staphylococcus aureus / Fibra de Algodón / Quitosano / Escherichia coli / Retardadores de Llama / Antibacterianos Idioma: En Revista: Int J Biol Macromol Año: 2024 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Staphylococcus aureus / Fibra de Algodón / Quitosano / Escherichia coli / Retardadores de Llama / Antibacterianos Idioma: En Revista: Int J Biol Macromol Año: 2024 Tipo del documento: Article