Your browser doesn't support javascript.
loading
Biomechanical evaluation of different medial column fixation patterns for valgus pilon fractures.
Wang, Bing-Hao; Zhang, Bin-Bin; Gong, Zi-Ling; Mei, Jiong; Luo, Cong-Feng; Zhu, Yi.
Afiliación
  • Wang BH; Department of Orthopaedic Surgery, Shanghai Sixth People's Hospital, Affiliated to Shanghai Jiao Tong University School of Medicine, 600 Yishan Road, Shanghai, 200233, China.
  • Zhang BB; Department of Orthopaedic Surgery, Shanghai Sixth People's Hospital, Affiliated to Shanghai Jiao Tong University School of Medicine, 600 Yishan Road, Shanghai, 200233, China.
  • Gong ZL; Department of Orthopaedic Surgery, Shanghai Sixth People's Hospital, Affiliated to Shanghai Jiao Tong University School of Medicine, 600 Yishan Road, Shanghai, 200233, China.
  • Mei J; Department of Orthopaedic Surgery, Shanghai Sixth People's Hospital, Affiliated to Shanghai Jiao Tong University School of Medicine, 600 Yishan Road, Shanghai, 200233, China.
  • Luo CF; Department of Orthopaedic Surgery, Shanghai Sixth People's Hospital, Affiliated to Shanghai Jiao Tong University School of Medicine, 600 Yishan Road, Shanghai, 200233, China. luocongfeng@sjtu.edu.cn.
  • Zhu Y; Department of Orthopaedic Surgery, Shanghai Sixth People's Hospital, Affiliated to Shanghai Jiao Tong University School of Medicine, 600 Yishan Road, Shanghai, 200233, China. tzjzzy@163.com.
BMC Musculoskelet Disord ; 25(1): 533, 2024 Jul 11.
Article en En | MEDLINE | ID: mdl-38992608
ABSTRACT

BACKGROUND:

The purpose of this study was to perform a biomechanical analysis to compare different medial column fixation patterns for valgus pilon fractures in a case-based model.

METHODS:

Based on the fracture mapping, 48 valgus pilon fracture models were produced and assigned into four groups with different medial column fixation patterns no fixation (NF), K-wires (KW), intramedullary screws (IS), and locking compression plate (LCP). Each group contained wedge-in and wedge-out subgroups. After fixing each specimen on the machine, gradually increased axial compressive loads were applied with a load speed of one millimeter per minute. The maximum peak force was set at 1500 N. Load-displacement curves were generated and the axial stiffness was calculated. Five different loads of 200 N, 400 N, 600 N, 800 N, 1000 N were selected for analysis. The specimen failure was defined as resultant loading displacement over 3 mm.

RESULTS:

For the wedge-out models, Group-IS showed less displacement (p < 0.001), higher axial stiffness (p < 0.01), and higher load to failure (p < 0.001) than Group-NF. Group-KW showed comparable displacement under loads of 200 N, 400 N and 600 N with both Group-IS and Group-LCP. For the wedge-in models, no statistical differences in displacement, axial stiffness, or load to failure were observed among the four groups. Overall, wedge-out models exhibited less axial stiffness than wedge-in models (all p < 0.01).

CONCLUSIONS:

Functional reduction with stable fixation of the medial column is essential for the biomechanical stability of valgus pilon fractures and medial column fixation provides the enough biomechanical stability for this kind of fracture in the combination of anterolateral fixation. In detail, the K-wires can provide a provisional stability at an early stage. Intramedullary screws are strong enough to provide the medial column stability as a definitive fixation. In future, this technique can be recommended for medial column fixation as a complement for holistic stability in high-energy valgus pilon fractures.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Fracturas de la Tibia / Placas Óseas Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: BMC Musculoskelet Disord Asunto de la revista: FISIOLOGIA / ORTOPEDIA Año: 2024 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Fracturas de la Tibia / Placas Óseas Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: BMC Musculoskelet Disord Asunto de la revista: FISIOLOGIA / ORTOPEDIA Año: 2024 Tipo del documento: Article País de afiliación: China