Your browser doesn't support javascript.
loading
Comparison of the dosimetry of scandium-43 and scandium-44 patient organ doses in relation to commonly used gallium-68 for imaging neuroendocrine tumours.
Gomes, Carlos Vinícius; Mendes, Bruno Melo; Paixão, Lucas; Gnesin, Silvano; Müller, Cristina; van der Meulen, Nicholas P; Strobel, Klaus; Fonseca, Telma Cristina Ferreira; Lima, Thiago Viana Miranda.
Afiliación
  • Gomes CV; Graduate School for Cellular and Biomedical Sciences, University of Bern, 3012, Bern, Switzerland. carlos.gomesferreira@students.unibe.ch.
  • Mendes BM; Post-graduation Program in Nuclear Sciences and Techniques, Department of Nuclear Engineering, Federal University of Minas Gerais, Belo Horizonte, Brazil. carlos.gomesferreira@students.unibe.ch.
  • Paixão L; Nuclear Technology Development Center - CDTN/CNEN, Belo Horizonte, Brazil.
  • Gnesin S; Department of Anatomy and Imaging, Federal University of Minas Gerais, Belo Horizonte, Brazil.
  • Müller C; Institute of Radiation Physics, Lausanne University Hospital, University of Lausanne, Lausanne, Switzerland.
  • van der Meulen NP; Center for Radiopharmaceutical Sciences, Paul Scherrer Institute (PSI), Villigen, Switzerland.
  • Strobel K; Center for Radiopharmaceutical Sciences, Paul Scherrer Institute (PSI), Villigen, Switzerland.
  • Fonseca TCF; Laboratory of Radiochemistry, Paul Scherrer Institute (PSI), Villigen, Switzerland.
  • Lima TVM; Institute of Radiology and Nuclear Medicine, Luzerner Kantonsspital - LUKS, Lucerne, Switzerland.
EJNMMI Phys ; 11(1): 61, 2024 Jul 15.
Article en En | MEDLINE | ID: mdl-39004681
ABSTRACT

BACKGROUND:

Several research groups have explored the potential of scandium radionuclides for theragnostic applications due to their longer half-lives and equal or similar coordination chemistry between their diagnostic and therapeutic counterparts, as well as lutetium-177 and terbium-161, respectively. Unlike the gallium-68/lutetium-177 pair, which may show different in-vivo uptake patterns, the use of scandium radioisotopes promises consistent behaviour between diagnostic and therapeutic radiopeptides. An advantage of scandium's longer half-life over gallium-68 is the ability to study radiopeptide uptake over extended periods and its suitability for centralized production and distribution. However, concerns arise from scandium-44's decay characteristics and scandium-43's high production costs. This study aimed to evaluate the dosimetric implications of using scandium radioisotopes with somatostatin analogues against gallium-68 for PET imaging of neuroendocrine tumours.

METHODS:

Absorbed dose per injected activity (AD/IA) from the generated time-integrated activity curve (TIAC) were estimated using the radiopeptides [43/44/44mSc]Sc- and [68Ga]Ga-DOTATATE. The kidneys, liver, spleen, and red bone marrow (RBM) were selected for dose estimation studies. The EGSnrc and MCNP6.1 Monte Carlo (MC) codes were used with female (AF) and male (AM) ICRP phantoms. The results were compared to Olinda/EXM software, and the effective dose concentrations assessed, varying composition between the scandium radioisotopes.

RESULTS:

Our findings showed good agreement between the MC codes, with - 3 ± 8% mean difference. Kidneys, liver, and spleen showed differences between the MC codes (min and max) in a range of - 4% to 8%. This was observed for both phantoms for all radiopeptides used in the study. Compared to Olinda/EXM the largest observed difference was for the RBM, of 21% for the AF and 16% for the AM for scandium- and gallium-based radiopeptides. Despite the differences, our findings showed a higher absorbed dose on [43/44Sc]Sc-DOTATATE compared to its 68Ga-based counterpart.

CONCLUSION:

This study found that [43/44Sc]Sc-DOTATATE delivers a higher absorbed dose to organs at risk compared to [68Ga]Ga-DOTATATE, assuming equal distribution. This is due to the longer half-life of scandium radioisotopes compared to gallium-68. However, calculated doses are within acceptable ranges, making scandium radioisotopes a feasible replacement for gallium-68 in PET imaging, potentially offering enhanced diagnostic potential with later timepoint imaging.
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: EJNMMI Phys Año: 2024 Tipo del documento: Article País de afiliación: Suiza

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: EJNMMI Phys Año: 2024 Tipo del documento: Article País de afiliación: Suiza