Your browser doesn't support javascript.
loading
Agreement Between Apple Watch and Actical Step Counts in a Community Setting: Cross-Sectional Investigation From the Framingham Heart Study.
Spartano, Nicole L; Zhang, Yuankai; Liu, Chunyu; Chernofsky, Ariel; Lin, Honghuang; Trinquart, Ludovic; Borrelli, Belinda; Pathiravasan, Chathurangi H; Kheterpal, Vik; Nowak, Christopher; Vasan, Ramachandran S; Benjamin, Emelia J; McManus, David D; Murabito, Joanne M.
Afiliación
  • Spartano NL; Section of Endocrinology, Diabetes, Nutrition, and Weight Management, Boston University Chobanian and Avedisian School of Medicine, Boston, MA, United States.
  • Zhang Y; Boston University's and National Heart, Lung, and Blood Institute's Framingham Heart Study, Framingham, MA, United States.
  • Liu C; Boston University School of Public Health, Boston, MA, United States.
  • Chernofsky A; Boston University School of Public Health, Boston, MA, United States.
  • Lin H; Boston University School of Public Health, Boston, MA, United States.
  • Trinquart L; University of Massachusetts Chan Medical School, Worcester, MA, United States.
  • Borrelli B; Institute for Clinical Research and Health Policy Studies, Tufts Medical Center, Boston, MA, United States.
  • Pathiravasan CH; Tufts Clinical and Translational Science Institute, Tufts University, Boston, MA, United States.
  • Kheterpal V; Boston University Henry M. Goldman School of Dental Medicine, Center for Behavioral Science Research, Boston, MA, United States.
  • Nowak C; Boston University School of Public Health, Boston, MA, United States.
  • Vasan RS; Care Evolution, Ann Arbor, MI, United States.
  • Benjamin EJ; Care Evolution, Ann Arbor, MI, United States.
  • McManus DD; Boston University's and National Heart, Lung, and Blood Institute's Framingham Heart Study, Framingham, MA, United States.
  • Murabito JM; Section of Preventive Medicine and Epidemiology, Department of Medicine, Boston University Chobanian and Avedisian School of Medicine, Boston, MA, United States.
JMIR Biomed Eng ; 9: e54631, 2024 Jul 24.
Article en En | MEDLINE | ID: mdl-39047284
ABSTRACT

BACKGROUND:

Step counting is comparable among many research-grade and consumer-grade accelerometers in laboratory settings.

OBJECTIVE:

The purpose of this study was to compare the agreement between Actical and Apple Watch step-counting in a community setting.

METHODS:

Among Third Generation Framingham Heart Study participants (N=3486), we examined the agreement of step-counting between those who wore a consumer-grade accelerometer (Apple Watch Series 0) and a research-grade accelerometer (Actical) on the same days. Secondarily, we examined the agreement during each hour when both devices were worn to account for differences in wear time between devices.

RESULTS:

We studied 523 participants (n=3223 person-days, mean age 51.7, SD 8.9 years; women n=298, 57.0%). Between devices, we observed modest correlation (intraclass correlation [ICC] 0.56, 95% CI 0.54-0.59), poor continuous agreement (29.7%, n=957 of days having steps counts with ≤15% difference), a mean difference of 499 steps per day higher count by Actical, and wide limits of agreement, roughly ±9000 steps per day. However, devices showed stronger agreement in identifying who meets various steps per day thresholds (eg, at 8000 steps per day, kappa coefficient=0.49), for which devices were concordant for 74.8% (n=391) of participants. In secondary analyses, in the hours during which both devices were worn (n=456 participants, n=18,760 person-hours), the correlation was much stronger (ICC 0.86, 95% CI 0.85-0.86), but continuous agreement remained poor (27.3%, n=5115 of hours having step counts with ≤15% difference) between devices and was slightly worse for those with mobility limitations or obesity.

CONCLUSIONS:

Our investigation suggests poor overall agreement between steps counted by the Actical device and those counted by the Apple Watch device, with stronger agreement in discriminating who meets certain step thresholds. The impact of these challenges may be minimized if accelerometers are used by individuals to determine whether they are meeting physical activity guidelines or tracking step counts. It is also possible that some of the limitations of these older accelerometers may be improved in newer devices.
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: JMIR Biomed Eng Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: JMIR Biomed Eng Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos