Your browser doesn't support javascript.
loading
Compositional Characterization of Syngas-Based Glycolide Using Gas Chromatogram-Mass Spectrometry and Electrospray Ionization High-Resolution Mass Spectrometry.
Zhang, Yachun; Chen, Junyang; He, Jianhua; Li, Shuofan; Wang, Yuanfeng; Zhang, Yahe; Shi, Quan.
Afiliación
  • Zhang Y; CHN Energy Yulin Chemical Co., Ltd., Yulin 719000, China.
  • Chen J; State Key Laboratory of Heavy Oil Processing, China University of Petroleum, Beijing 102249, China.
  • He J; CHN Energy Yulin Chemical Co., Ltd., Yulin 719000, China.
  • Li S; State Key Laboratory of Heavy Oil Processing, China University of Petroleum, Beijing 102249, China.
  • Wang Y; State Key Laboratory of Heavy Oil Processing, China University of Petroleum, Beijing 102249, China.
  • Zhang Y; State Key Laboratory of Heavy Oil Processing, China University of Petroleum, Beijing 102249, China.
  • Shi Q; State Key Laboratory of Heavy Oil Processing, China University of Petroleum, Beijing 102249, China.
Molecules ; 29(16)2024 Aug 08.
Article en En | MEDLINE | ID: mdl-39202840
ABSTRACT
Polyglycolic acid (PGA) is a biologically friendly material with a wide range of applications. The production of dimethyl oxalate using coal-based syngas and the hydrogenation of dimethyl oxalate can produce the polymerization raw material of PGA, glycolide, which requires a methyl glycolate polymerization and depolymerization process. The intermediate products of the production process were analyzed using gas chromatogram-mass spectrometry (GC-MS) and Orbitrap mass spectrometry (Orbitrap MS), which revealed the presence of cyclic and linear PGAs with different capped ends. The impurities present in the oligomer were mostly methyl-capped PGA and were retained in the subsequent depolymerization process to glycolide, solvent washing can be used to remove this part of the impurity and ultimately obtain a refined glycolide product. Furthermore, it is proposed that the use of the specialized Kendrick Mass Defect (KMD) to plot and analyze PGA compounds obtained using mass spectrometry can enable the direct classification of PGAs without the need for exact molecular formula assignment.
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Molecules / Molecules (Basel) Asunto de la revista: BIOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Molecules / Molecules (Basel) Asunto de la revista: BIOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: China