Colorimetric correcting for sample concentration in stool samples.
Delanghe, Joris R; Van Elslande, Jan; Godefroid, Maaike J; Thieuw Barroso, Alexandre M; De Buyzere, Marc L; Maenhout, Thomas M.
Afiliación
  • Delanghe JR; Labo Maenhout, Waregem, Belgium.
  • Van Elslande J; Labo Maenhout, Waregem, Belgium.
  • Godefroid MJ; Labo Maenhout, Waregem, Belgium.
  • Thieuw Barroso AM; Labo Maenhout, Waregem, Belgium.
  • De Buyzere ML; Labo Maenhout, Waregem, Belgium.
  • Maenhout TM; Labo Maenhout, Waregem, Belgium.
Clin Chem Lab Med ; 2024 Sep 23.
Article en En | MEDLINE | ID: mdl-39301583
ABSTRACT

OBJECTIVES:

Fecal immunochemical tests (FIT) for hemoglobin are currently considered the screening investigation of choice for colorectal cancer and are worldwide recommended. Similarly, fecal calprotectin is a widely used test for monitoring intestinal inflammation. The pre-analytical issues regarding stool samples have hardly been dealt with and are difficult to solve. Currently, there are no reference analytes available which allow to correct test results for the variable water content of the stool sample. Studies on preanalytics of stool samples have generally focused on sample preparation and sample storage, but generally have paid little attention to the variability in sample hydration and sample composition.

METHODS:

Stercobilin is a stable heme metabolite which is abundant in stool. Stercobilin concentration can be simply assayed in stool extracts using colorimetry (determination of the I index). Serum indices (H, I and L) and bilirubin concentration of fecal extracts were determined on a Atellica Platform (Siemens).

RESULTS:

The inter-individual variation of stercobilin was found to be high. Assaying stercobilin allows to correct for stool sample dilution. The median value of the I-index was used as a reference for correcting the data. Correcting fecal blood results for sample dilution resulted in a significant increase in positive tests (from 9.3 to 11.7 %). For calprotectin, correction resulted in 3.1 % extra positive results and 7.7 % negative results.

CONCLUSIONS:

Except in the case of obstructive jaundice, this correction can be applied. Correcting test results of common fecal analytes like FIT and calprotectin may result in a better tailored test interpretation.