Your browser doesn't support javascript.
loading
Circadian variation of ventricular arrhythmia recurrences after cardioverter-defibrillator implantation in patients with healed myocardial infarcts.
Mallavarapu, C; Pancholy, S; Schwartzman, D; Callans, D J; Heo, J; Gottlieb, C D; Marchlinski, F E.
Afiliación
  • Mallavarapu C; Clinical Electrophysiology Laboratory, Philadelphia, Heart Institute, Presbyterian Medical Center of Philadelphia, Pennsylvania 19104, USA.
Am J Cardiol ; 75(16): 1140-4, 1995 Jun 01.
Article en En | MEDLINE | ID: mdl-7762501
ABSTRACT
Past studies using Holter monitoring and retrospective reviews of death certificates have documented peak occurrence of sudden death and nonsustained ventricular tachycardia (VT) in the morning hours. We used the Ventritex Cadence device (Ventritex, Sunnyvale, California) which documents the date and time of all stored arrhythmias leading to device therapy to evaluate the circadian pattern of sustained ventricular arrhythmia recurrence. Mean follow-up after defibrillator implantation was 628 +/- 285 days. All 390 patients had at least 1 episode (range 1 to 43) of sustained VT documented from analysis of the stored electrograms associated with an arrhythmia event. Stored electrograms were available for review and analysis in 3,041 device detections; 349 stored events were excluded because they did not fulfill the diagnostic criteria for VT or failed to document the onset of the ventricular arrhythmia at the beginning of the recorded event of the arrhythmia episode. Criteria for the diagnosis of VT or ventricular fibrillation were met in 2,692 arrhythmia episodes occurring in 390 patients. There was circadian variation for ventricular arrhythmia recurrence for the whole patient group with the data fit to the sinusoidal density function f(t) = 126 - 51 x cos (-57 + 2 pi t/24) - 25 x sin (63 + 2 pi t/12) (p < 0.0001). Ventricular arrhythmia occurrence rate was lowest between 200 and 300 A.M., and highest between 1000 and 1100 A.M. In addition, the same circadian pattern was demonstrated regardless of patient age, gender, left ventricular ejection fraction (< 35% or > or = 35%), and VT cycle length (< 300 or > or = 300 ms).(ABSTRACT TRUNCATED AT 250 WORDS)
Asunto(s)
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Fibrilación Ventricular / Cardioversión Eléctrica / Ritmo Circadiano / Taquicardia Ventricular / Desfibriladores Implantables / Infarto del Miocardio Tipo de estudio: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Am J Cardiol Año: 1995 Tipo del documento: Article País de afiliación: Estados Unidos
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Fibrilación Ventricular / Cardioversión Eléctrica / Ritmo Circadiano / Taquicardia Ventricular / Desfibriladores Implantables / Infarto del Miocardio Tipo de estudio: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Am J Cardiol Año: 1995 Tipo del documento: Article País de afiliación: Estados Unidos