Human aortic valve allografts elicit a donor-specific immune response.
J Thorac Cardiovasc Surg
; 112(5): 1260-6; discussion 1266-7, 1996 Nov.
Article
en En
| MEDLINE
| ID: mdl-8911322
OBJECTIVE: The nature and magnitude of the immunologic response to implantation of human cryopreserved aortic valve allografts was investigated. METHODS: Twenty aortic valve allograft recipients were investigated for donor-specific antibody and T-cell-mediated responses with serial flow cytometric and microlymphocytotoxic crossmatch assays and one-way mixed lymphocyte cultures. RESULTS: Donor-specific immunoglobulin G antibodies to class I and II human leukocyte antigens were first detected in the serum of all aortic valve allograft recipients at 30 days after implantation and persisted in substantial amounts in all but one of the recipients at day 365. Recipient T-cell alloreactivity toward donor lymphocytes was significantly increased at day 30 compared with levels before and 10 days after operation. CONCLUSIONS: Cryopreserved aortic valve allografts elicit a substantial allogeneic response in recipients. This alloreactivity may contribute to the observed morphologic changes in aortic valve allografts and eventual long-term deterioration of allograft function.
Buscar en Google
Colección:
01-internacional
Banco de datos:
MEDLINE
Asunto principal:
Válvula Aórtica
/
Inmunología del Trasplante
Límite:
Adult
/
Aged
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
J Thorac Cardiovasc Surg
Año:
1996
Tipo del documento:
Article
País de afiliación:
Australia