Your browser doesn't support javascript.
loading
Phasic coronary flow pattern and flow reserve in patients with left bundle branch block and normal coronary arteries.
Skalidis, E I; Kochiadakis, G E; Koukouraki, S I; Parthenakis, F I; Karkavitsas, N S; Vardas, P E.
Afiliação
  • Skalidis EI; Department of Cardiology, University Hospital of Heraklion, Crete, Greece.
J Am Coll Cardiol ; 33(5): 1338-46, 1999 Apr.
Article em En | MEDLINE | ID: mdl-10193736
ABSTRACT

OBJECTIVES:

The purpose of this study was to determine whether scintigraphic myocardial perfusion defects in patients with left bundle branch block (LBBB) and normal coronary arteries are related to abnormalities in coronary flow velocity pattern and/or coronary flow reserve.

BACKGROUND:

Septal or anteroseptal defects on exercise myocardial perfusion scintigraphy are common in patients with LBBB and normal coronary arteries.

METHODS:

Thirteen patients (7 men, age 61+/-8 years) with LBBB and normal coronary arteries underwent stress thallium-201 scintigraphy and cardiac catheterization. In all patients and in 11 control subjects coronary blood flow parameters were calculated from Doppler measurements of flow velocity in the left anterior descending coronary artery (LAD) before and after adenosine administration.

RESULTS:

The time to maximum peak diastolic flow velocity was significantly longer both for the seven patients with (134+/-19 ms) and for the six without (136+/-7 ms) exercise perfusion defects than for controls (105+/-12 ms, p < 0.05), whereas the acceleration was slower (170+/-54, 186+/-42 and 279+/-96 cm/s2, respectively, p < 0.05). Coronary flow reserve in the patients with exercise perfusion defects (2.7+/-0.3) was significantly lower than in those without (3.7+/-0.5, p < 0.05) or in the control group (3.4+/-0.5, p < 0.05).

CONCLUSIONS:

Patients with LBBB have an impairment of early diastolic blood flow in the LAD due to an increase in early diastolic compressive resistance resulting from delayed ventricular relaxation. Furthermore, exercise scintigraphic perfusion defects in these patients are associated with a reduced coronary flow reserve, indicating abnormalities of microvascular function in the same vascular territory.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Bloqueio de Ramo / Circulação Coronária / Vasos Coronários Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Am Coll Cardiol Ano de publicação: 1999 Tipo de documento: Article País de afiliação: Grécia
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Bloqueio de Ramo / Circulação Coronária / Vasos Coronários Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Am Coll Cardiol Ano de publicação: 1999 Tipo de documento: Article País de afiliação: Grécia