Your browser doesn't support javascript.
loading
Formulations and nebulizer performance.
O'Riordan, Thomas G.
Afiliação
  • O'Riordan TG; Pulmonary/Critical Care Division, Health Sciences Center, State University of New York at Stony Brook, Stony Brook, New York 11794-8172, USA. toriordan@mail.som.sunysb.edu
Respir Care ; 47(11): 1305-12; discussion 1312-3, 2002 Nov.
Article em En | MEDLINE | ID: mdl-12425745
ABSTRACT
To deliver a drug by nebulization, the drug must first be dispersed in a liquid (usually aqueous) medium. After application of a dispersing force (either a jet of gas or ultrasonic waves), the drug particles are contained within the aerosol droplets, which are then inhaled. Some drugs readily dissolve in water, whereas others need a cosolvent such as ethanol or propylene glycol. Some drugs are delivered as suspensions, and the efficiency of nebulizers can be different for solutions and suspensions. Solutions are delivered more efficiently with most devices. In general, conventional ultrasonic nebulizers should not be used to aerosolize suspensions, because of low efficiency. Newer strategies to improve the delivery of non-water-soluble drugs include the use of liposomes and the milling of the drug into very small "nanoparticles." In addition to the active therapeutic ingredient and solvents, drug formulations may include buffers (the solubility of some medications is influenced by pH), stabilizers, and, in the case of multi-dose preparations, antibacterial agents. Though formulations are designed to optimize drug solubility and stability, changes in formulation can also affect inhaled mass, particle size, and treatment time, though the differences between nebulizer brands probably have a greater impact than differences in formulation. Ultrasonic and jet nebulizers may damage protein and other complex agents through heat or shear stress. Additives to multi-dose formulations, especially antimicrobial and chelating agents, may cause adverse events, so there is a trend towards single-use, preservative-free vials.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Nebulizadores e Vaporizadores / Coloides / Aerossóis Limite: Humans Idioma: En Revista: Respir Care Ano de publicação: 2002 Tipo de documento: Article País de afiliação: Estados Unidos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Nebulizadores e Vaporizadores / Coloides / Aerossóis Limite: Humans Idioma: En Revista: Respir Care Ano de publicação: 2002 Tipo de documento: Article País de afiliação: Estados Unidos