Your browser doesn't support javascript.
loading
Determination of simvastatin-derived HMG-CoA reductase inhibitors in biomatrices using an automated enzyme inhibition assay with radioactivity detection.
Liu, Lida; Zhang, Rena; Zhao, Jamie J; Rogers, John D; Hsieh, John Y K; Fang, Wei; Matuszewski, Bogdan K; Dobrinska, Michael R.
Afiliação
  • Liu L; Drug Metabolism, Merck Research Laboratories, WP 75A-303, West Point, PA 19486, USA. lida_liu@merck.com
J Pharm Biomed Anal ; 32(1): 107-23, 2003 Apr 24.
Article em En | MEDLINE | ID: mdl-12852453
ABSTRACT
A robust, automated enzyme inhibition assay method was developed and validated for the determination of HMG-CoA reductase inhibitory activities in plasma and urine samples following simvastatin (SV) administration. The assay was performed on Tecan Genesis 150 and 200 systems equipped with 8-probe and 96-well plates. Plasma samples containing HMG-CoA reductase inhibitors were treated with acetonitrile for protein precipitation before being incubated with HMG-CoA reductase, [14C]-HMG-CoA, and NADPH for a fixed length of time at a fixed temperature. The product, [14C]-mevalonic acid, was lactonized and separated from excess substrate via a small ion exchange resin column, and radioactivity was counted on a scintillation counter. HMG-CoA reductase inhibitors were measured before and after base hydrolysis. The two values obtained for each sample are referred to as 'active' and 'total' HMG-CoA reductase inhibitor concentrations. Simvastatin acid (SVA), the beta-hydroxy acid of SV, was used as a standard to generate a calibration curve of HMG-CoA reductase activity versus SVA concentration (ng/ml). Three calibration ranges, 0.4-20, 2-50, and 50, 100 ng/ml, in human and animal plasma and urine were validated. The assay precision was less than 8.5%, CV in plasma and less than 10.4% in urine. The assay accuracy was 93.6-103.0 and 98.1-103.9% for the 0.4 20 and 2-50 ng/ml calibration ranges, respectively, in human plasma, and was 97.3-105.1, 94.4- 105.2, and 90.2-95.7%, for calibration range 5-100 ng/ml in rat plasma, dog plasma and human urine, respectively.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Inibidores de Hidroximetilglutaril-CoA Redutases / Sinvastatina Tipo de estudo: Diagnostic_studies Limite: Animals / Humans Idioma: En Revista: J Pharm Biomed Anal Ano de publicação: 2003 Tipo de documento: Article País de afiliação: Estados Unidos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Inibidores de Hidroximetilglutaril-CoA Redutases / Sinvastatina Tipo de estudo: Diagnostic_studies Limite: Animals / Humans Idioma: En Revista: J Pharm Biomed Anal Ano de publicação: 2003 Tipo de documento: Article País de afiliação: Estados Unidos