Late incomplete stent apposition and focal vessel expansion after bare metal stenting.
Nakamura, Mamoo; Kataoka, Toru; Honda, Yasuhiro; Bonneau, Heidi N; Hibi, Kiyoshi; Kitamura, Katsuhiro; Tamai, Hideo; Aizawa, Tadanori; Yock, Paul G; Fitzgerald, Peter J.
Afiliação
  • Nakamura M; Center for Research in Cardiovascular Interventions, Stanford University, Stanford, California 94305-5637, USA.
Am J Cardiol ; 92(10): 1217-9, 2003 Nov 15.
Article em En | MEDLINE | ID: mdl-14609603
ABSTRACT
Late incomplete stent apposition was observed in 2.4% of the 412 stented segments studied by serial intravascular ultrasound analyses. Most of these phenomena and all late vessel expansions with incomplete stent apposition developed in vessels in which lesions were treated by atherectomy before stenting, suggesting a potential association between mechanical injury from debulking and these phenomena.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Falha de Prótese / Endotélio Vascular / Stents / Aterectomia Coronária / Doença das Coronárias / Implante de Prótese Vascular Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Am J Cardiol Ano de publicação: 2003 Tipo de documento: Article País de afiliação: Estados Unidos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Falha de Prótese / Endotélio Vascular / Stents / Aterectomia Coronária / Doença das Coronárias / Implante de Prótese Vascular Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Am J Cardiol Ano de publicação: 2003 Tipo de documento: Article País de afiliação: Estados Unidos