Your browser doesn't support javascript.
loading
Long-distance frequency dissemination with a resolution of 10(-17).
Daussy, C; Lopez, O; Amy-Klein, A; Goncharov, A; Guinet, M; Chardonnet, C; Narbonneau, F; Lours, M; Chambon, D; Bize, S; Clairon, A; Santarelli, G; Tobar, M E; Luiten, A N.
Afiliação
  • Daussy C; LPL, Laboratoire de Physique des Lasers, UMR 7538 C.N.R.S., Université Paris 13, 99, avenue J.-B. Clément, 93430 Villetaneuse, France.
Phys Rev Lett ; 94(20): 203904, 2005 May 27.
Article em En | MEDLINE | ID: mdl-16090250
ABSTRACT
We use a new technique to disseminate microwave reference signals along ordinary optical fiber. The fractional frequency resolution of a link of 86 km in length is 10(-17) for a one day integration time, a resolution higher than the stability of the best microwave or optical clocks. We use the link to compare the microwave reference and a CO2/OsO4 frequency standard that stabilizes a femtosecond laser frequency comb. This demonstrates a resolution of 3 x 10(-14) at 1 s. An upper value of the instability introduced by the femtosecond laser-based synthesizer is estimated as 1 x 10(-14) at 1 s.
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Phys Rev Lett Ano de publicação: 2005 Tipo de documento: Article País de afiliação: França
Buscar no Google