Your browser doesn't support javascript.
loading
[Comparative study of 18 F-fluorodeoxyglucose imaging with a dual-head coincidence gamma camera with dobutamine stress echocardiography for the assessment of myocardial viability]. / Análise comparativa da captação de 18 fluordesoxiglicose por câmara de cintilação e sistema de coincidência e a ecocardiografia de estresse pela dobutamina na detecção de viabilidade miocárdica.
Farsky, Pedro Silvio; Piegas, Leopoldo Soares; Gimenes, Vera Marcia; Petisco, Ana Claudia G; Duarte, Paulo S; Martins, Luiz Roberto; Issa, Mario; Paulista, Paulo Paredes; Sousa, José Eduardo Moraes Rego.
Afiliação
  • Farsky PS; Instituto Dante Pazzanese de Cardiologia e Fleury, Centro de Medicina Diagnóstica, São Paulo, SP. farskyp@uol.com.br
Arq Bras Cardiol ; 85(2): 105-9, 2005 Aug.
Article em Pt | MEDLINE | ID: mdl-16113848
ABSTRACT

OBJECTIVE:

To compare Dual-Head coincidence gamma camera (DCD-AC) with dobutamine stress echocardiography (DSE) in viability assessment, using functional recovery as the gold standard.

METHODS:

Twenty-one patients were prospectively studied, with coronary artery disease and severe left ventricular dysfunction undergoing DSE and DCD-AC at baseline and DSE three months after revascularization.

RESULTS:

Of the 290 segments analyzed, 83% were akinetic, 15% hypokinetic and 2% dyskinetic at rest. DSE identified 68% of these segments as non-viable. DCD-AC identified 56% of these segments as normal (dysfunctional segments with preserved metabolism and perfusion), 30% as viable (preserved metabolism and reduced perfusion) and 14% as non-viable (reduced perfusion and metabolism). Of the DSE non-viable segments, DCD-AC identified 80% as normal or viable and 19.9% as non-viable (p<0.001). In hypokinetic segments viability and normal segments were detected in a higher proportion by both methods (p<0.001). DSE sensibility and specificity were 48.3% and 78.1% respectively. DCD-AC sensibility and specificity was 92.2% and 20.0%. DCD-AC identifies a higher incidence of function improvement in normal segments than in viable and non-viable.

CONCLUSION:

DCD-AC classified as normal or viable most of the non-viable DSE segments. In assessment of functional recovery segments after three months, DCD-AC showed a high sensibility but low specificity.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Disfunção Ventricular Esquerda / Compostos Radiofarmacêuticos / Fluordesoxiglucose F18 / Ecocardiografia sob Estresse / Contração Miocárdica Limite: Female / Humans / Male / Middle aged Idioma: Pt Revista: Arq Bras Cardiol Ano de publicação: 2005 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Disfunção Ventricular Esquerda / Compostos Radiofarmacêuticos / Fluordesoxiglucose F18 / Ecocardiografia sob Estresse / Contração Miocárdica Limite: Female / Humans / Male / Middle aged Idioma: Pt Revista: Arq Bras Cardiol Ano de publicação: 2005 Tipo de documento: Article