Your browser doesn't support javascript.
loading
Serum free light chain analysis and urine immunofixation electrophoresis in patients with multiple myeloma.
Nowrousian, Mohammad R; Brandhorst, Dieter; Sammet, Christiane; Kellert, Michaela; Daniels, Rainer; Schuett, Philipp; Poser, Miriam; Mueller, Siemke; Ebeling, Peter; Welt, Anja; Bradwell, Arthur R; Buttkereit, Ulrike; Opalka, Bertram; Flasshove, Michael; Moritz, Thomas; Seeber, Siegfried.
Afiliação
  • Nowrousian MR; Department of Internal Medicine (Cancer Research), West German Cancer Center, University Hospital of Essen Medical School, Essen, Germany. nowrousian@uni-essen.de
Clin Cancer Res ; 11(24 Pt 1): 8706-14, 2005 Dec 15.
Article em En | MEDLINE | ID: mdl-16361557
ABSTRACT

PURPOSE:

Retrospective studies have shown that immunoassays measuring free light chains (FLC) in serum are useful for diagnosis and monitoring of multiple myeloma. This study prospectively evaluates the use of FLC assays and, for the first time, investigates the relationship between serum FLC concentrations and the presence and detectability of Bence Jones (BJ) proteins in the urine. PATIENTS AND

METHODS:

Three hundred seventy-eight paired samples of serum and urine were tested from 82 patients during the course of their disease. The sensitivities of serum FLC analysis and urine immunofixation electrophoresis (IFE) in detecting monoclonal FLC were compared. Serum FLC concentrations required for producing BJ proteins detected by IFE were determined.

RESULTS:

Abnormal FLC were present in 54% of serum samples compared with 25% by urine tests. In abnormal serum samples for kappa or lambda, the sensitivity of IFE to detect the respective BJ proteins in urine were 51% and 35% and the median serum FLC concentrations required to produce detectable BJ proteins were 113 and 278 mg/L. Renal excretions of monoclonal FLC increased with serum concentrations, but excretions significantly decreased at high serum concentrations combined with renal dysfunction.

CONCLUSION:

Serum FLC assays are significantly more sensitive for detecting monoclonal FLC than urine IFE analysis. They also have the advantage of FLC quantification and are more reliable for monitoring disease course and response to treatment.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Proteína de Bence Jones / Imunoensaio / Imunoeletroforese / Cadeias Leves de Imunoglobulina / Mieloma Múltiplo Tipo de estudo: Diagnostic_studies / Evaluation_studies / Observational_studies Limite: Humans Idioma: En Revista: Clin Cancer Res Assunto da revista: NEOPLASIAS Ano de publicação: 2005 Tipo de documento: Article País de afiliação: Alemanha
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Proteína de Bence Jones / Imunoensaio / Imunoeletroforese / Cadeias Leves de Imunoglobulina / Mieloma Múltiplo Tipo de estudo: Diagnostic_studies / Evaluation_studies / Observational_studies Limite: Humans Idioma: En Revista: Clin Cancer Res Assunto da revista: NEOPLASIAS Ano de publicação: 2005 Tipo de documento: Article País de afiliação: Alemanha