Your browser doesn't support javascript.
loading
Development and validation of a multiwavelength spatial domain near-infrared oximeter to detect cerebral hypoxia-ischemia.
Nelson, Lindsey A; McCann, John C; Loepke, Andres W; Wu, Jun; Ben Dor, Baruch; Kurth, C Dean.
Afiliação
  • Nelson LA; Cincinnati Children's Hospital Medical Center, University of Cincinnati College of Medicine, Department of Anesthesia and Pediatrics, Institute of Pediatric Anesthesia, Cincinnati, Ohio 45229-3039, USA.
J Biomed Opt ; 11(6): 064022, 2006.
Article em En | MEDLINE | ID: mdl-17212545
ABSTRACT
Detection of cerebral hypoxia-ischemia in infants remains problematic, as current monitors in clinical practice are impractical, insensitive, or nonspecific. Our study develops a multiwavelength spatial domain construct for near-infrared spectroscopy (NIRS) to detect cerebral hypoxia-ischemia and evaluates the construct in several models. The NIRS probe contains photodiode detectors 2, 3, and 4 cm from a three-wavelength, light-emitting diode. A construct determines cerebral O(2) saturation based on spatial domain principles. Device performance and construct validity are examined in in-vitro models simulating the brain, and in piglets subjected to hypoxia, hypoxia-ischemia, and hyperoxic conditions using a weighted average of arterial and cerebral venous O(2) saturation measured by CO-oximetry. The results in the brain models verify key equations in the construct and demonstrate reliable performance of the device. In piglets, the device measures cerebral O(2) saturation with bias +/-4% and precision +/-8%. In conclusion, this NIRS device accurately detects cerebral hypoxia-ischemia and is of a design that is practical for clinical application.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Oxigênio / Espectrofotometria Infravermelho / Algoritmos / Oximetria / Diagnóstico por Computador / Hipóxia-Isquemia Encefálica Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Animals Idioma: En Revista: J Biomed Opt Assunto da revista: ENGENHARIA BIOMEDICA / OFTALMOLOGIA Ano de publicação: 2006 Tipo de documento: Article País de afiliação: Estados Unidos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Oxigênio / Espectrofotometria Infravermelho / Algoritmos / Oximetria / Diagnóstico por Computador / Hipóxia-Isquemia Encefálica Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Animals Idioma: En Revista: J Biomed Opt Assunto da revista: ENGENHARIA BIOMEDICA / OFTALMOLOGIA Ano de publicação: 2006 Tipo de documento: Article País de afiliação: Estados Unidos