Your browser doesn't support javascript.
loading
Comparative performance of the Roche COBAS Amplicor assay and an in-house real-time PCR assay for diagnosis of Chlamydia trachomatis infection.
Jalal, Hamid; Al-Suwaine, Abdulrahman; Stephen, Hannah; Carne, Christopher; Sonnex, Christopher.
Afiliação
  • Jalal H; Clinical Microbiology and Public Health Laboratory, Box 236, Addenbrooke's Hospital, Hills Road, Cambridge CB2 2QW, UK.
  • Al-Suwaine A; King Faisal Specialist Hospital and Research Centre, Riyadh, Saudi Arabia.
  • Stephen H; Clinical Microbiology and Public Health Laboratory, Box 236, Addenbrooke's Hospital, Hills Road, Cambridge CB2 2QW, UK.
  • Carne C; Department of Genitourinary Medicine, Clinic 1A, Box 38, Addenbrooke's Hospital, Hills Road, Cambridge CB2 2QQ, UK.
  • Sonnex C; Department of Genitourinary Medicine, Clinic 1A, Box 38, Addenbrooke's Hospital, Hills Road, Cambridge CB2 2QQ, UK.
J Med Microbiol ; 56(Pt 3): 320-322, 2007 Mar.
Article em En | MEDLINE | ID: mdl-17314360
ABSTRACT
This study investigated the comparative performance of the Amplicor assay and an in-house semi-automated, multiplex real-time PCR for the diagnosis of genital chlamydial infection. Four different assays, the COBAS Amplicor CT test (Amplicor PCR), in-house real-time PCR (IHRT-PCR), in-house nested cryptic plasmid PCR and in-house nested major outer membrane protein PCR, were performed on genital swabs from 1000 consecutive patients attending a genitourinary medicine clinic. The samples were designated true positive if Chlamydia trachomatis DNA was detected by at least two of the four above-mentioned assays while a sample was defined as true negative if C. trachomatis DNA was detected in only one or none of the assays. By this criterion, there were 129 true positive and 871 true negative samples for C. trachomatis DNA in this cohort. Amplicor PCR designated 144 samples positive 128 (89%) of 144 samples were true positive and 16 (11%) were false positive. IHRT-PCR detected 126 of 129 true positive samples and did not generate any false positive results. The sensitivity of IHRT-PCR was comparable with, and specificity was higher than, Amplicor PCR for the diagnosis of genital chlamydial infection.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Infecções por Chlamydia / Chlamydia trachomatis / Reação em Cadeia da Polimerase / Doenças dos Genitais Femininos / Doenças dos Genitais Masculinos Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Med Microbiol Ano de publicação: 2007 Tipo de documento: Article País de afiliação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Infecções por Chlamydia / Chlamydia trachomatis / Reação em Cadeia da Polimerase / Doenças dos Genitais Femininos / Doenças dos Genitais Masculinos Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Med Microbiol Ano de publicação: 2007 Tipo de documento: Article País de afiliação: Reino Unido