An improved time-of-flight method for cluster deposition and ion-scattering experiments.
Rev Sci Instrum
; 79(1): 013905, 2008 Jan.
Article
em En
| MEDLINE
| ID: mdl-18248048
ABSTRACT
A molecular beam apparatus has been developed for deposition and scattering experiments of size-selected clusters. The new setup combines a bimetallic laser ablation cluster source with a collinear time-of-flight mass spectrometer. Mass selection is achieved with a pulsed electrostatic mirror. A significantly improved transmission in combination with a reduction of the kinetic energy distribution of the mass selected clusters has been obtained. Without further modification of the apparatus, surface-induced dissociation of mass selected tin clusters has been investigated, demonstrating the possibility to combine cluster beam deposition and scattering experiments.