Your browser doesn't support javascript.
loading
Physiologic response to varying levels of pressure support and neurally adjusted ventilatory assist in patients with acute respiratory failure.
Colombo, Davide; Cammarota, Gianmaria; Bergamaschi, Valentina; De Lucia, Marta; Corte, Francesco Della; Navalesi, Paolo.
Afiliação
  • Colombo D; Università degli Studi del Piemonte Orientale A. Avogadro, SCDU Anestesia, Terapia Intensiva e Rianimazione Generale, Azienda Ospedaliera Universitaria Maggiore della Carità, Novara, Italy.
Intensive Care Med ; 34(11): 2010-8, 2008 Nov.
Article em En | MEDLINE | ID: mdl-18629471
ABSTRACT

OBJECTIVE:

Neurally adjusted ventilatory assist (NAVA) is a new mode wherein the assistance is provided in proportion to diaphragm electrical activity (EAdi). We assessed the physiologic response to varying levels of NAVA and pressure support ventilation (PSV).

SETTING:

ICU of a University Hospital. PATIENTS Fourteen intubated and mechanically ventilated patients. DESIGN AND PROTOCOL Cross-over, prospective, randomized controlled trial. PSV was set to obtain a VT/kg of 6-8 ml/kg with an active inspiration. NAVA was matched with a dedicated software. The assistance was decreased and increased by 50% with both modes. The six assist levels were randomly applied. MEASUREMENTS Arterial blood gases (ABGs), tidal volume (VT/kg), peak EAdi, airway pressure (Paw), neural and flow-based timing. Asynchrony was calculated using the asynchrony index (AI).

RESULTS:

There was no difference in ABGs regardless of mode and assist level. The differences in breathing pattern, ventilator assistance, and respiratory drive and timing between PSV and NAVA were overall small at the two lower assist levels. At the highest assist level, however, we found greater VT/kg (9.1 +/- 2.2 vs. 7.1 +/- 2 ml/kg, P < 0.001), and lower breathing frequency (12 +/- 6 vs. 18 +/- 8.2, P < 0.001) and peak EAdi (8.6 +/- 10.5 vs. 12.3 +/- 9.0, P < 0.002) in PSV than in NAVA; we found mismatch between neural and flow-based timing in PSV, but not in NAVA. AI exceeded 10% in five (36%) and no (0%) patients with PSV and NAVA, respectively (P < 0.05).

CONCLUSIONS:

Compared to PSV, NAVA averted the risk of over-assistance, avoided patient-ventilator asynchrony, and improved patient-ventilator interaction.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Respiração Artificial / Síndrome do Desconforto Respiratório / Diafragma / Cuidados Críticos Tipo de estudo: Clinical_trials / Observational_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Intensive Care Med Ano de publicação: 2008 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Respiração Artificial / Síndrome do Desconforto Respiratório / Diafragma / Cuidados Críticos Tipo de estudo: Clinical_trials / Observational_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Intensive Care Med Ano de publicação: 2008 Tipo de documento: Article País de afiliação: Itália