Your browser doesn't support javascript.
loading
Whole-body diffusion-weighted magnetic resonance imaging in the staging of oncological patients: comparison with positron emission tomography computed tomography (PET-CT) in a pilot study.
Stecco, A; Romano, G; Negru, M; Volpe, D; Saponaro, A; Costantino, S; Sacchetti, G; Inglese, E; Alabiso, O; Carriero, A.
Afiliação
  • Stecco A; SCDU Radiologia, Università del Piemonte Orientale A. Avogadro, C.so Mazzini 18, 28100, Novara, Italy. astecco@sirm.org
Radiol Med ; 114(1): 1-17, 2009 Feb.
Article em En, It | MEDLINE | ID: mdl-19082787
ABSTRACT

PURPOSE:

The aim of this pilot study was to compare positron emission tomography computed tomography (PET-CT) and whole-body DWIBS in staging oncological patients to determine the staging accuracy of whole-body DWIBS. MATERIALS AND

METHODS:

We initiated a prospective, blinded investigation on 29 patients affected by oncological diseases (n=14) or lymphoma (n=15), who underwent fluorodeoxyglucose (FDG)-based PET-CT and whole-body DWIBS for restaging purposes. Magnetic resonance (MR) imaging was conducted with a multistack (n=4) DWIBS pulse sequence. Images were read independently by two experienced radiologists and one nuclear physician. Statistical analysis assessed interobserver agreement and diagnostic accuracy.

RESULTS:

Whole-body DWIBS had a room occupation time of 20 min. Mean postprocessing time was 15 min (range 10-17 min). Mean reading time was 20 min for reader 1 (range 15-25 min) and 18 min for reader 2 (range 13-22 min). Interobserver agreement was almost perfect (=0.93). Reader 1 had a sensitivity of 89.07%, a specificity of 98.5%, and an accuracy of 97.65%, with a positive predictive value (PPV) of 85.48% and a negative predictive value (NPV) of 98.91%. Reader 2 had a sensitivity of 87.39%, a specificity of 98.39% and a diagnostic accuracy of 97.8%, with a PPV of 88.13% and a NPV of 98.75%.

CONCLUSIONS:

The whole-body DWIBS protocol provided a fast whole-body examination with high specificity and NPV. One major bias of the study was the inclusion of patients with diffuse disease and advanced disease stage and the heterogeneity of the neoplastic diseases included.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Imagem de Difusão por Ressonância Magnética / Tomografia por Emissão de Pósitrons / Imagem Corporal Total / Neoplasias Tipo de estudo: Evaluation_studies / Guideline / Prognostic_studies Limite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En / It Revista: Radiol Med Ano de publicação: 2009 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Imagem de Difusão por Ressonância Magnética / Tomografia por Emissão de Pósitrons / Imagem Corporal Total / Neoplasias Tipo de estudo: Evaluation_studies / Guideline / Prognostic_studies Limite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En / It Revista: Radiol Med Ano de publicação: 2009 Tipo de documento: Article País de afiliação: Itália