Characterisation of the "vulnerable" coronary plaque by multi-detector computed tomography: a correlative study with intravascular ultrasound-derived radiofrequency analysis of plaque composition.
EuroIntervention
; 4(3): 318-23, 2008 Nov.
Article
em En
| MEDLINE
| ID: mdl-19110804
ABSTRACT
AIMS:
To assess plaque characteristics by multi-detector computed tomography angiography in patients with known coronary artery disease and to compare these findings with those obtained with intravascular ultrasound-derived radiofrequency analysis of plaque composition. METHODS ANDRESULTS:
By computed tomography, lesions were classified on the basis of Hounsfield Units as non-calcified, calcified, or mixed. By intravascular ultrasound-derived radiofrequency analysis, plaques were classified according to the relative composition of components with specific backscatter characteristics (necrotic core, fibrous, fibro-fatty, calcium). Thin cap fibroatheroma (defined as necrotic core component >10% without evidence of fibrotic cap, calcium >5%, remodelling index >1.05) was considered as vulnerable plaque. Seventy-eight plaques were analysed. By computed tomography, 22 plaques were classified as non-calcified and 56 as mixed. A higher incidence of mixed plaques was observed among lesions causing unstable angina and non-ST elevation myocardial infarction compared to stable angina (76% vs 38%, p=0.04). Plaque composition by radiofrequency analysis was significantly different between mixed and non-calcified plaques by computed tomography. The calcium content was 6.0+/-3.2% vs 2.5+/-1.8% (p=0.001), necrotic core was 14.0+/-6.9% vs 7.5+/-5.6% (p=0.03) and fibrous tissue was 59.0+/-7.5% vs 67.0+/-5.9% (p=0.03), for mixed vs non-calcified plaques, respectively. Positive, negative predictive value and diagnostic accuracy for detection of vulnerable plaque by computed tomography was 77, 54 and 59%.CONCLUSIONS:
Mixed plaque by computed tomography correlates with plaque composition as determined by intravascular ultrasound-derived radiofrequency analysis. However, the present diagnostic accuracy of computed tomography is not high enough to support its use for non invasive detection of vulnerable coronary plaque.
Buscar no Google
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Doença da Artéria Coronariana
/
Tomografia Computadorizada por Raios X
/
Angiografia Coronária
/
Ultrassonografia de Intervenção
Tipo de estudo:
Prognostic_studies
Limite:
Aged
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
EuroIntervention
Assunto da revista:
ANGIOLOGIA
/
CARDIOLOGIA
/
TERAPEUTICA
Ano de publicação:
2008
Tipo de documento:
Article
País de afiliação:
Bélgica