Your browser doesn't support javascript.
loading
Removal of BCG artifacts from EEG recordings inside the MR scanner: a comparison of methodological and validation-related aspects.
Vanderperren, Katrien; De Vos, Maarten; Ramautar, Jennifer R; Novitskiy, Nikolay; Mennes, Maarten; Assecondi, Sara; Vanrumste, Bart; Stiers, Peter; Van den Bergh, Bea R H; Wagemans, Johan; Lagae, Lieven; Sunaert, Stefan; Van Huffel, Sabine.
Afiliação
  • Vanderperren K; Katholieke Universiteit Leuven, Department of Electrical Engineering, ESAT-SCD, Leuven, Belgium. katrien.vanderperren@esat.kuleuven.be
Neuroimage ; 50(3): 920-34, 2010 Apr 15.
Article em En | MEDLINE | ID: mdl-20074647
Multimodal approaches are of growing interest in the study of neural processes. To this end much attention has been paid to the integration of electroencephalographic (EEG) and functional magnetic resonance imaging (fMRI) data because of their complementary properties. However, the simultaneous acquisition of both types of data causes serious artifacts in the EEG, with amplitudes that may be much larger than those of EEG signals themselves. The most challenging of these artifacts is the ballistocardiogram (BCG) artifact, caused by pulse-related electrode movements inside the magnetic field. Despite numerous efforts to find a suitable approach to remove this artifact, still a considerable discrepancy exists between current EEG-fMRI studies. This paper attempts to clarify several methodological issues regarding the different approaches with an extensive validation based on event-related potentials (ERPs). More specifically, Optimal Basis Set (OBS) and Independent Component Analysis (ICA) based methods were investigated. Their validation was not only performed with measures known from previous studies on the average ERPs, but most attention was focused on task-related measures, including their use on trial-to-trial information. These more detailed validation criteria enabled us to find a clearer distinction between the most widely used cleaning methods. Both OBS and ICA proved to be able to yield equally good results. However, ICA methods needed more parameter tuning, thereby making OBS more robust and easy to use. Moreover, applying OBS prior to ICA can optimize the data quality even more, but caution is recommended since the effect of the additional ICA step may be strongly subject-dependent.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Balistocardiografia / Processamento de Sinais Assistido por Computador / Encéfalo / Imageamento por Ressonância Magnética / Artefatos / Eletroencefalografia Tipo de estudo: Prognostic_studies Limite: Adult / Female / Humans / Male Idioma: En Revista: Neuroimage Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Bélgica

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Balistocardiografia / Processamento de Sinais Assistido por Computador / Encéfalo / Imageamento por Ressonância Magnética / Artefatos / Eletroencefalografia Tipo de estudo: Prognostic_studies Limite: Adult / Female / Humans / Male Idioma: En Revista: Neuroimage Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Bélgica