ABSTRACT

PURPOSE:

To show that 4D Flow is a clinically viable tool for evaluation of collateral blood flow and demonstration of distorted blood flow patterns in patients with treated and untreated aortic coarctation. MATERIALS AND

METHODS:

Time-resolved, 3D phase contrast magnetic resonance imaging (MRI) (4D Flow) was used to assess blood flow in the thoracic aorta of 34 individuals 26 patients with coarctation (22 after surgery or stent placement) and eight healthy volunteers.

RESULTS:

Direct comparison of blood flow calculated with 2D and 4D phase contrast data at standard levels for analysis in coarctation patients showed good correlation and agreement (correlation coefficient r = 0.99, limits of agreement = -20% to 20% for collateral blood flow calculations). Abnormal blood flow patterns were demonstrated at peak systole with 4D Flow visualization techniques in the descending thoracic aorta of patients but not volunteers. Marked helical flow was seen in 9 of 13 patients with angulated aortic arch geometries after coarctation repair. Vortical flow was seen in regions of poststenotic dilation.

CONCLUSION:

4D Flow is a fast and reliable means of evaluating collateral blood flow in patients with aortic coarctation in order to establish hemodynamic significance. It also can detect distorted blood flow patterns in the descending aorta after coarctation repair.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Coartação Aórtica / Algoritmos / Interpretação de Imagem Assistida por Computador / Angiografia por Ressonância Magnética / Imageamento Tridimensional / Técnicas de Imagem de Sincronização Cardíaca Tipo de estudo: Diagnostic_studies Limite: Adult / Female / Humans / Male Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Coartação Aórtica / Algoritmos / Interpretação de Imagem Assistida por Computador / Angiografia por Ressonância Magnética / Imageamento Tridimensional / Técnicas de Imagem de Sincronização Cardíaca Tipo de estudo: Diagnostic_studies Limite: Adult / Female / Humans / Male Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Estados Unidos