Nonlinear registration of serial coronary CT angiography (CCTA) for assessment of changes in atherosclerotic plaque.
Med Phys
; 37(2): 885-96, 2010 Feb.
Article
em En
| MEDLINE
| ID: mdl-20229898
PURPOSE: Coronary CT angiography (CCTA) is a high-resolution three-dimensional imaging technique for the evaluation of coronary arteries in suspected or confirmed coronary artery disease (CAD). Coregistration of serial CCTA scans would allow precise superimposition of images obtained at two different points in time, which could aid in recognition of subtle changes and precise monitoring of coronary plaque progression or regression. To this end, the authors aimed at developing a fully automatic nonlinear volume coregistration for longitudinal CCTA scan pairs. METHODS: The algorithm combines global displacement and local deformation using nonlinear volume coregistration with a volume-preserving constraint. Histogram matching of intensities between two serial scans is performed prior to nonlinear coregistration with dense nonparametric local deformation in which sum of squared differences is used as a similarity measure. The approximate segmentation of coronary arteries obtained from commercially available software provides initial anatomical landmarks for the coregistration algorithm that help localize and emphasize the structure of interest. To avoid possible bias caused by incorrect segmentation, the authors convolve the Gaussian kernel with the segmented binary coronary tree mask and define an extended weighted region of interest. A multiresolution approach is employed to represent coarse-to-fine details of both volumes and the energy function is optimized using a gradient descent method. The authors applied the algorithm in ten paired CCTA datasets (20 scans in total) obtained within 10.7 +/- 5.7 months from each other on a dual source CT scanner to monitor progression of CAD. RESULTS: Serial CCTA coregistration was successful in 9/10 cases as visually confirmed. The global displacement and local deformation of target registration error obtained from four anatomical landmarks were 2.22 +/- 1.15 and 1.56 +/- 0.74 mm, respectively, and the inverse consistency error of local deformation was 0.14 +/- 0.06 mm. The observer variability between two expert observers was 1.31 +/- 0.91 mm. CONCLUSIONS: The proposed coregistration algorithm demonstrates potential to accurately register serial CCTA scans, which may allow direct comparison of calcified and noncalcified atherosclerotic plaque changes between the two scans.
Buscar no Google
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Doença da Artéria Coronariana
/
Reconhecimento Automatizado de Padrão
/
Interpretação de Imagem Radiográfica Assistida por Computador
/
Tomografia Computadorizada por Raios X
/
Armazenamento e Recuperação da Informação
/
Técnica de Subtração
/
Angiografia Coronária
Tipo de estudo:
Diagnostic_studies
/
Prognostic_studies
Limite:
Humans
Idioma:
En
Revista:
Med Phys
Ano de publicação:
2010
Tipo de documento:
Article
País de afiliação:
Estados Unidos