Your browser doesn't support javascript.
loading
Methyl vinyl ketone--identification and quantification of adducts to N-terminal valine in human hemoglobin.
von Stedingk, Hans; Davies, Ronnie; Rydberg, Per; Törnqvist, Margareta.
Afiliação
  • von Stedingk H; Department of Materials and Environmental Chemistry, Arrhenius Laboratory, Stockholm University, Svante Arrhenius väg 16C, SE-106 91 Stockholm, Sweden. hans.stedingk@mmk.su.se
J Chromatogr B Analyt Technol Biomed Life Sci ; 878(27): 2491-6, 2010 Oct 01.
Article em En | MEDLINE | ID: mdl-20399154
ABSTRACT
Adducts to N-terminal valines in Hb have been shown useful as biomarkers of exposure to electrophilic compounds. Adducts from many compounds have earlier been measured with a modified Edman degradation method using a GC-MS/MS method. A recently developed method, the adduct FIRE procedure™, adopted for analysis by LC-MS/MS, has been applied in this study. With this method a fluorescein isothiocyanate (FITC) reagent is used to measure adducts (R) from electrophiles with a modified Edman procedure. By using LC-MS/MS in product ion scan mode, a new peak was identified and the obtained MS data indicated that this adduct could originate from methyl vinyl ketone (MVK). Incubation of human-, sheep- and bovine blood with MVK increased the signal of the identified peak. By comparing the LC-MS/MS data from the unknown background peak with data obtained from synthesized fluorescein thiohydantoin (FTH) standards of the MVK adduct to valine and d(8)-valine, the identity of this adduct was confirmed. The MVK adduct was shown present in human blood (∼35 pmol/g globin, n=3) and only just above LOD in bovine blood, n=1 (LOD=2 pmol/g globin). MVK reacts, in similarity with acrylamide, via Michael addition. MVK is known to occur in the environment and has earlier been observed in biological samples, which means that there are possible natural and anthropogenic exposure sources. Analysis of an Hb adduct from MVK in humans has to our knowledge not been described before.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Valina / Butanonas / Hemoglobinas Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Suécia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Valina / Butanonas / Hemoglobinas Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Suécia