Your browser doesn't support javascript.
loading
Non-contrast renal artery MRA using an inflow inversion recovery steady state free precession technique (Inhance): comparison with 3D contrast-enhanced MRA.
Glockner, James F; Takahashi, Naoki; Kawashima, Akira; Woodrum, David A; Stanley, David W; Takei, Naoyuki; Miyoshi, Mitsuharu; Sun, Wei.
Afiliação
  • Glockner JF; Mayo Clinic, Rochester, Minnesota 55905, USA. Glockner.james@mayo.edu
J Magn Reson Imaging ; 31(6): 1411-8, 2010 Jun.
Article em En | MEDLINE | ID: mdl-20512894
ABSTRACT

PURPOSE:

To assess the performance of a three-dimensional (3D) non-contrast respiratory-triggered steady state free precession (SSFP) pulse sequence for detection of renal artery stenosis. MATERIALS AND

METHODS:

A total of 64 patients who had non-contrast MR angiography (NC MRA) and 3D contrast-enhanced MRA (CE MRA) performed during the same exam and three patients who had NC MRA followed by conventional catheter angiography within one month of the MRI exam were included in this retrospective study. Two blinded readers evaluated NC MRA images for the presence of significant renal artery stenosis and also rated their diagnostic confidence and evaluated the images for artifact. A similar analysis was performed for CE MRA images by two additional blinded readers, and discrepancies were resolved by consensus reading.

RESULTS:

The 67 patients had 168 main and accessory renal arteries, with significant (>50%) stenosis in 34 arteries on CE MRA or conventional angiography. The two NC MRA readers had sensitivity and specificity for detection of significant stenosis of 94%/82% and 82%/87% respectively on a per renal artery basis.

CONCLUSION:

There was good agreement between CE MRA and NC MRA for detection of significant renal artery stenosis. This technique should prove useful in evaluating patients with suspected renovascular hypertension who are unable to undergo CE MRA.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artéria Renal / Angiografia por Ressonância Magnética / Meios de Contraste / Imageamento Tridimensional / Rim Tipo de estudo: Observational_studies Limite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artéria Renal / Angiografia por Ressonância Magnética / Meios de Contraste / Imageamento Tridimensional / Rim Tipo de estudo: Observational_studies Limite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Estados Unidos