Your browser doesn't support javascript.
loading
Prevention of retinopathy of prematurity in preterm infants through changes in clinical practice and SpO2technology.
Castillo, Armando; Deulofeut, Richard; Critz, Ann; Sola, Augusto.
Afiliação
  • Castillo A; Northeast Georgia Medical Center, Gainesville, USA.
Acta Paediatr ; 100(2): 188-92, 2011 Feb.
Article em En | MEDLINE | ID: mdl-20825604
ABSTRACT

AIM:

To identify whether pulse oximetry technology is associated with decreased retinopathy of prematurity (ROP) and laser treatment.

METHODS:

Inborn infants <1250 g who had eye exams were compared at two centres in three periods. In Period 1, SpO2 target was ≥93% and pulse oximetry technology was the same in both Centres. In Period 2, guidelines for SpO2 88-93% were implemented at both centres and Centre B changed to oximeters with signal extraction technology (SET(®)) while Centre A did not, but did so in Period 3. One ophthalmology department performed eye exams using international criteria.

RESULTS:

In 571 newborns <1250 g, birth weight and gestational age were similar in the different periods and centres. At Centre A, severe ROP and need for laser remained the same in Periods 1 and 2, decreasing in Period 3-6% and 3%, respectively. At Centre B, severe ROP decreased from 12% (Period 1) to 5% (Period 2) and need for laser decreased from 5% to 3%, remaining low in Period 3.

CONCLUSION:

In a large group of inborn infants <1250 g, a change in clinical practice in combination with pulse oximetry with Masimo SET, but not without it, led to significant reduction in severe ROP and need for laser therapy. Pulse oximetry selection is important in managing critically ill infants.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Retinopatia da Prematuridade / Oximetria Tipo de estudo: Clinical_trials / Diagnostic_studies / Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Male / Newborn Idioma: En Revista: Acta Paediatr Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Retinopatia da Prematuridade / Oximetria Tipo de estudo: Clinical_trials / Diagnostic_studies / Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Male / Newborn Idioma: En Revista: Acta Paediatr Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Estados Unidos