ABSTRACT

OBJECTIVES:

The purpose of this study was to evaluate the impact on lesion detectability of fast imaging protocols using 18F-FDG and a 3-dimensional LSO-based PET/CT scanner.

METHODS:

An anthropomorphic thoracic phantom was used simulating the anatomical structures of radioactivity distribution for the upper torso of an underweight patient. Irregularly shaped targets of small dimensions, the zeolites, were located inside the phantom in an unpredictable position for the observers. Target-to background ratios and target dimensions were selected in order to sample the range of detectability. Repeated imaging was performed to acquire PET images with varying emission scan duration (ESD) of 1, 2, 3 and 4 min/bed and background activity concentrations of 10, 5 and 3 kBq/mL in the torso cavity. Three observers ranked the targets and a receiver operating characteristic analysis was performed for each acquisition protocol.

RESULTS:

Detection performances improved when passing from a short (ESD = 1 min) protocol to longer (ESD C 2 min) protocols. This improvement was established with adequate statistical significance.

CONCLUSIONS:

Short image acquisition times of 1 min/bed using 18F-FDG and the specific scanner model considered in the study lead to reduced lesion detectability and should be avoided also in underweight patients.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tórax / Radiografia Torácica / Tomografia Computadorizada por Raios X / Curva ROC / Imagens de Fantasmas / Tomografia por Emissão de Pósitrons Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Ann Nucl Med Assunto da revista: MEDICINA NUCLEAR Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tórax / Radiografia Torácica / Tomografia Computadorizada por Raios X / Curva ROC / Imagens de Fantasmas / Tomografia por Emissão de Pósitrons Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Ann Nucl Med Assunto da revista: MEDICINA NUCLEAR Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Itália