Expanded polytetrafluoroethylene sutures have been used for the replacement of chordae tendineae since 1985, especially for mitral valve prolapse. There are only a few reports of artificial chordae tendineae to treat tricuspid valve regurgitation. We report on a 72-year-old woman in NYHA class III preoperatively, who underwent successful tricuspid valve repair after preoperative echocardiography revealed tricuspid valve regurgitation grade IV, caused by prolapse of the anterior leaflet (A1-A2) and annular dilatation. Tricuspid valve repair was performed using artificial chords consisting of two polytetrafluoroethylene sutures and a ring annuloplasty. Postoperative echocardiography revealed mild tricuspid valve regurgitation of less than 1°, even after three years. Gore-Tex® sutures as used in mitral valve repair are an excellent option to replace chordae tendineae in tricuspid valve prolapse. This approach represents a safe and effective technique for tricuspid valve repair.