Your browser doesn't support javascript.
loading
HiSStology: high spectral and spatial resolution magnetic resonance imaging detection of vasculature validated by histology and micro-computed tomography.
Haney, Chad R; Pelizzari, Charles A; Foxley, Sean; Zamora, Marta A; Mustafi, Devkumar; Tretiakova, Maria; Li, Shihong; Fan, Xiaobing; Karczmar, Gregory S.
Afiliação
  • Haney CR; Department of Radiology, University of Chicago, Chicago, IL 60637, USA. chaney@uchicago.edu
Mol Imaging ; 10(3): 187-96, 2011 Jun.
Article em En | MEDLINE | ID: mdl-21443840
High spectral and spatial resolution (HiSS) data, acquired with echo-planar spectroscopic imaging (EPSI), can be used to acquire water spectra from each small image voxel. These images are sensitive to changes in local susceptibility caused by superparamagnetic iron oxide particles (SPIO); therefore, we hypothesized that images derived from HiSS data are very sensitive to tumor neovasculature following injection of SPIO. Accurate image registration was used to validate HiSS detection of neovasculature with histology and micro-computed tomographic (microCT) angiography. Athymic nude mice and Copenhagen rats were inoculated with Dunning AT6.1 prostate tumor cells in the right hind limb. The tumor region was imaged pre- and post-intravenous injection of SPIO. Three-dimensional assemblies of the CD31-stained histologic slices of the mouse legs and the microCT images of the rat vascular casts were registered with EPSI. The average distance between HiSS-predicted regions of high vascular density on magnetic resonance imaging and CD31-stained regions on histology was 200 µm. Similarly, vessels identified by HiSS in the rat images coincided with vasculature in the registered microCT image. The data demonstrate a strong correlation between tumor vasculature identified using HiSS and two gold standards: histology and microCT angiography.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vasos Sanguíneos / Imageamento por Ressonância Magnética / Interpretação de Imagem Assistida por Computador / Microtomografia por Raio-X Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: En Revista: Mol Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vasos Sanguíneos / Imageamento por Ressonância Magnética / Interpretação de Imagem Assistida por Computador / Microtomografia por Raio-X Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: En Revista: Mol Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Estados Unidos