Your browser doesn't support javascript.
loading
Examination of the efficacy and safety of intraoperative gastroscopic testing of the gastrojejunal anastomosis in laparoscopic Roux Y gastric bypass surgery.
Mohos, Elemer; Schmaldienst, Elizabeth; Richter, Doris; Prager, Manfred.
Afiliação
  • Mohos E; Department of General Surgery, Territory Hospital Oberwart, Dornburggasse 80, Oberwart, 7400, Austria. mohose@freemail.hu
Obes Surg ; 21(10): 1592-6, 2011 Oct.
Article em En | MEDLINE | ID: mdl-21538176
The laparoscopic Roux Y gastric bypass (LRYGB) is one of the most often performed bariatric surgical intervention. Intraoperative gastroscopy (IOG) seems to be reliable to decrease the leakage rate of gastrojejunal anastomosis (GJA) and of gastric pouch (GP). Our aim was to test the efficacy and the safety of this method. Two hundred fifty-two LRYGB operations were performed in our institution between 1 January 2008 and 1 January 2010. IOG is routinely made to test the integrity of GJA and of GP. Patients' dates were retrospectively analysed. The intragastric pressure developed during gastroscopy in humans was measured and compared with pressure values led to destruction (positive air test) of the GJA and/or GP in animal models (hybrid pigs). Stomach and bowel wall samples from the test animals without pressure strain, with pressure strain developed at gastroscopy in humans and with pressure strains led to destruction of GJA and/or GP were histologically examined. IOG resulted in six of our cases (2.3%) positive air test. There was no anastomosis insufficiency in postoperative period. Mean pressure during IOG was 32 mmHg, mean time of examination was 3.8 min and mean maximal pressure was 43 mmHg in humans. The mean pressure leading to positive air test in pigs was 150 mmHg. We could not detect any microscopical difference between stomach and jejunum samples without pressure strain and after pressure strain developed in humans during the gastroscopy. We conclude that intraoperative gastroscopy is an effective and safe method to test the integrity of GJA and GP in LRYGB surgery.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estômago / Derivação Gástrica / Gastroscopia / Fístula Anastomótica / Jejuno Tipo de estudo: Etiology_studies / Prognostic_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Obes Surg Assunto da revista: METABOLISMO Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Áustria

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estômago / Derivação Gástrica / Gastroscopia / Fístula Anastomótica / Jejuno Tipo de estudo: Etiology_studies / Prognostic_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Obes Surg Assunto da revista: METABOLISMO Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Áustria