Validation of Tikhonov adaptively regularized gamma variate fitting with 24-h plasma clearance in cirrhotic patients with ascites.
Wesolowski, Carl Adam; Ling, Lin; Xirouchakis, Elias; Burniston, Maria T; Puetter, Richard C; Babyn, Paul S; Giamalis, Ioannis G; Burroughs, Andrew K.
Afiliação
  • Wesolowski CA; Radiology, Memorial University of Newfoundland, St. John's, NL, Canada. carl.wesolowski@gmail.com
Eur J Nucl Med Mol Imaging ; 38(12): 2247-56, 2011 Dec.
Article em En | MEDLINE | ID: mdl-21881927
ABSTRACT

PURPOSE:

The aim was to compare late-time extrapolation of plasma clearance (CL) from Tikhonov adaptively regularized gamma variate fitting (Tk-GV) and from mono-exponential (E1) fitting.

METHODS:

Ten (51)Cr-ethylenediaminetetraacetic acid bolus IV studies in adults--8 with ascites--assessed for liver transplantation, with 12-16 plasma samples drawn from 5-min to 24-h, were fit with Tk-GV and E1 models and CL results were compared using Passing-Bablok fitting.

RESULTS:

The 24-h CL(Tk-GV) values ranged from 11.4 to 79.7 ml/min. Linear regression of 4- versus 24-h CL(Tk-GV) yielded no significant departure from a slope of 1, whereas the 4- versus 24-h CL(E1) slope, 1.56, was significantly increased. For CL(Tk-GV-24-h) versus CL(E1-24-h), there was a biased slope and intercept (0.85, 5.97 ml/min). Moreover, the quality of fitting of 24-h data was significantly better for Tk-GV than for E1, as follows. For 10 logarithm of concentration curves, higher r values were obtained for each Tk-GV fit (median 0.998) than for its corresponding E1 fit (median 0.965), with p < 0.0001 (paired t-test of z-statistics from Fisher r-z transformations). The E1 fit quality degraded with increasing V/W [volume of distribution (l) per kg body weight, p = 0.003]. However, Tk-GV fit quality versus V/W was uncorrelated (p = 0.8).

CONCLUSION:

CL(E1) values were dependent on sample time and the quality of fit was poor and degraded with increasing ascites, consistent with current opinion that CL(E1) is contraindicated in ascitic patients. CL(Tk-GV) was relatively more accurate and the good quality of fit was unaffected by ascites. CL(Tk-GV) was the preferred method for the accurate calculation of CL and was useful despite liver failure and ascites.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ascite / Técnica de Diluição de Radioisótopos / Diagnóstico por Computador / Ácido Edético / Cirrose Hepática / Testes de Função Hepática Tipo de estudo: Diagnostic_studies / Etiology_studies / Prognostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur J Nucl Med Mol Imaging Assunto da revista: MEDICINA NUCLEAR Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Canadá

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ascite / Técnica de Diluição de Radioisótopos / Diagnóstico por Computador / Ácido Edético / Cirrose Hepática / Testes de Função Hepática Tipo de estudo: Diagnostic_studies / Etiology_studies / Prognostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur J Nucl Med Mol Imaging Assunto da revista: MEDICINA NUCLEAR Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Canadá