Validation study on the accuracy of echocardiographic measurements of right ventricular systolic function in pulmonary hypertension.
Sato, Takahiro; Tsujino, Ichizo; Ohira, Hiroshi; Oyama-Manabe, Noriko; Yamada, Asuka; Ito, Yoichi M; Goto, Chisa; Watanabe, Taku; Sakaue, Shinji; Nishimura, Masaharu.
Afiliação
  • Sato T; First Department of Medicine, Hokkaido University Hospital, Sapporo, Japan.
J Am Soc Echocardiogr ; 25(3): 280-6, 2012 Mar.
Article em En | MEDLINE | ID: mdl-22230250
ABSTRACT

BACKGROUND:

The accuracy of echocardiographic parameters of right ventricular (RV) function has not been sufficiently validated in patients with pulmonary hypertension (PH). The aim of this study was to evaluate whether echocardiographic measurements reliably reflect RV systolic function in PH using cardiac magnetic resonance imaging (CMRI)-derived RV ejection fraction (RVEF) as a gold standard.

METHODS:

A total of 37 consecutive patients with PH, 20 with pulmonary arterial hypertension, 12 with chronic thromboembolic PH, and five others, were prospectively studied. All patients underwent echocardiography, CMRI, and right-heart catheterization within a 1-week interval. Associations between five echocardiography-derived parameters of RV systolic function and CMRI-derived RVEF were evaluated.

RESULTS:

All five echocardiography-derived parameters were significantly correlated with CMRI-derived RVEF (percentage RV fractional shortening r = 0.48, P = .0011; percentage RV area change r = 0.40, P = .0083; tricuspid annular plane systolic excursion [TAPSE] r = 0.86, P < .0001; RV myocardial performance index r = -0.59, P < .0001; and systolic lateral tricuspid annular motion velocity r = 0.63, P < .0001). Compared with the other indices, TAPSE exhibited the highest correlation coefficient. Of the five echocardiographic measurements, only TAPSE significantly predicted CMRI-derived RVEF in multiple regression analysis (P < .0001). Intraobserver and interobserver reproducibility was favorable for all five indices and was particularly high for TAPSE and systolic lateral tricuspid annular motion velocity.

CONCLUSIONS:

Echocardiographic measurements are promising noninvasive indices of RV systolic function in patients with PH. In particular, TAPSE is superior to other indices in accuracy.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ecocardiografia / Função Ventricular Direita / Ventrículos do Coração / Hipertensão Pulmonar Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: J Am Soc Echocardiogr Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ecocardiografia / Função Ventricular Direita / Ventrículos do Coração / Hipertensão Pulmonar Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: J Am Soc Echocardiogr Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Japão