Minimally invasive input function for 2-18F-fluoro-A-85380 brain PET studies.
Zanotti-Fregonara, Paolo; Maroy, Renaud; Peyronneau, Marie-Anne; Trebossen, Régine; Bottlaender, Michel.
Afiliação
  • Zanotti-Fregonara P; Molecular Imaging Branch, National Institute of Mental Health, NIH, 10 Center Drive, MSC-1026, Bethesda, MD, 20892-2035, USA, zanottifregonp@mail.nih.gov.
Eur J Nucl Med Mol Imaging ; 39(4): 651-9, 2012 Apr.
Article em En | MEDLINE | ID: mdl-22231015
ABSTRACT

PURPOSE:

Quantitative neuroreceptor positron emission tomography (PET) studies often require arterial cannulation to measure input function. While population-based input function (PBIF) would be a less invasive alternative, it has only rarely been used in conjunction with neuroreceptor PET tracers. The aims of this study were (1) to validate the use of PBIF for 2-(18)F-fluoro-A-85380, a tracer for nicotinic receptors; (2) to compare the accuracy of measures obtained via PBIF to those obtained via blood-scaled image-derived input function (IDIF) from carotid arteries; and (3) to explore the possibility of using venous instead of arterial samples for both PBIF and IDIF.

METHODS:

Ten healthy volunteers underwent a dynamic 2-(18)F-fluoro-A-85380 brain PET scan with arterial and, in seven subjects, concurrent venous serial blood sampling. PBIF was obtained by averaging the normalized metabolite-corrected arterial input function and subsequently scaling each curve with individual blood samples. IDIF was obtained from the carotid arteries using a blood-scaling method. Estimated Logan distribution volume (V(T)) values were compared to the reference values obtained from arterial cannulation.

RESULTS:

For all subjects, PBIF curves scaled with arterial samples were similar in shape and magnitude to the reference arterial input function. The Logan V(T) ratio was 1.00 ± 0.05; all subjects had an estimation error <10%. IDIF gave slightly less accurate results (V(T) ratio 1.03 ± 0.07; eight of ten subjects had an error <10%). PBIF scaled with venous samples yielded inaccurate results (V(T) ratio 1.13 ± 0.13; only three of seven subjects had an error <10%). Due to arteriovenous differences at early time points, IDIF could not be calculated using venous samples.

CONCLUSION:

PBIF scaled with arterial samples accurately estimates Logan V(T) for 2-(18)F-fluoro-A-85380. Results obtained with PBIF were slightly better than those obtained with IDIF. Due to arteriovenous concentration differences, venous samples cannot be substituted for arterial samples.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Piridinas / Azetidinas / Encéfalo / Tomografia por Emissão de Pósitrons Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Humans / Male Idioma: En Revista: Eur J Nucl Med Mol Imaging Assunto da revista: MEDICINA NUCLEAR Ano de publicação: 2012 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Piridinas / Azetidinas / Encéfalo / Tomografia por Emissão de Pósitrons Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Humans / Male Idioma: En Revista: Eur J Nucl Med Mol Imaging Assunto da revista: MEDICINA NUCLEAR Ano de publicação: 2012 Tipo de documento: Article