[Elimination of interference in the determination of selenium in high purity tellurium by HG-AFS].
Ma, Ming-Yang; Su, Liu-Kun.
Afiliação
  • Ma MY; Guangdong Provincial Public Laboratory of Analysis and Testing Techdogy, China National Analytical Center, Guangzhou, Guangzhou 510070, China. cemmy0909@hotmail.com
Guang Pu Xue Yu Guang Pu Fen Xi ; 31(11): 3123-5, 2011 Nov.
Article em Zh | MEDLINE | ID: mdl-22242531
ABSTRACT
The samples were decomposed with HNCO3 +HCl, and Fe(3+)-citric acid mix solution was added to eliminate interferences. The elimination and mechanism of tellurium interference with selenium determination by HG-AFS were studied, and the residuary influence of NO3- and NO2- was investigated. The interference of ferric trichloride, hydrochloric acid, citric acid and PBH concentration with the fluorescence intensity of selenium was observed by the orthogonal test design combined with the mono-factor test. The detection limit was 0.15 microg x L(-1). The relative standard deviation of a solution containing 27.01 microg x L(-1) selenium in sample was in the range of 3.1%-4.2% (n = 11), and the recoveries of selenium were 96.1%-102.3%. The results obtained were satisfied, and the method was successfully applied to the determination of selenium in high purity tellurium samples.
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Idioma: Zh Revista: Guang Pu Xue Yu Guang Pu Fen Xi Ano de publicação: 2011 Tipo de documento: Article País de afiliação: China