Your browser doesn't support javascript.
loading
Comparison of fasting bioavailability among 100-mg commercial, 100-mg generic, and 50-mg chewable generic sildenafil tablets in healthy male Mexican volunteers: a single-dose, 3-period, crossover study.
Marcelín-Jiménez, Gabriel; Angeles-Moreno, Alionka P; Contreras-Zavala, Leticia; García-González, Alberto; Ramírez-San Juan, Eduardo.
Afiliação
  • Marcelín-Jiménez G; Global Bioanalytical Consulting, S.C., Mexico City, Mexico.
Clin Ther ; 34(3): 689-98, 2012 Mar.
Article em En | MEDLINE | ID: mdl-22386826
ABSTRACT

BACKGROUND:

Sildenafil citrate (SIL) was the first oral drug registered in Mexico for the treatment of erectile dysfunction. However, succinct pharmacokinetic data are available in the Mexican population.

OBJECTIVE:

The goals of the present work were (1) to design a specific method to quantify SIL plasma levels by using UPLC-MS/MS; (2) to compare oral SIL bioavailability in Mexican men with pharmacokinetic data in other populations; (3) to fulfill local regulatory requests; and (4) to describe the relative tolerability of a new 50-mg chewable tablet.

METHODS:

This was a randomized, single-dose, 3-period, 6-sequence crossover study in healthy male volunteers. In each period, subjects received single oral doses of 100 mg of sildenafil (1 commercial [reference(⁎)], 1 generic [test 1(†)], or 2 chewable generic tablets [test 2(‡)]), with a 4-day washout period between each dose. Serial blood samples were collected for up to 24 hours. SIL was measured in heparinized plasma by using a validated UPLC-MS/MS method. Pharmacokinetic parameters included C(max), T(max), AUC(0-24), and AUC(0-∞). Bioequivalence was established if 90% CIs for mean testreference ratios of log-transformed C(max) and AUC fell within the range of 0.80 to 1.25. Tolerability was assessed on the basis of a clinical interview with the subject and monitoring of vital signs.

RESULTS:

Demographic data showed a homogeneous population. Validation of analytical method proved to be linear within the range of 1 to 1000 ng/mL, with selectivity, accuracy, and precision. 90% CIs for test 1reference ratios were 86.52 to 113.56, 94.75 to 108.84, and 94.97 to 108.82 for the logarithm parameters C(max), AUC(0-24), and AUC(0-∞), respectively. The 90% CIs for the test 2reference ratios were 82.14 to 107.24, 98.26 to 112.56, and 99.19 to 113.34 for C(max), AUC(0-24), and AUC(0-∞). Regarding relative tolerability, slight cephalea was the most common adverse effect.

CONCLUSIONS:

The developed analytical method was validated in compliance with local requirements and was useful for sildenafil measurement. This single-dose study under fasting conditions suggests that both test products met the Mexican regulatory criteria for assuming bioequivalence in these healthy, male Mexican volunteers. The clinical data suggest that the chewable tablets were well tolerated by volunteers.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Piperazinas / Sulfonas / Vasodilatadores / Medicamentos Genéricos Tipo de estudo: Clinical_trials / Prognostic_studies Limite: Adolescent / Adult / Humans / Male / Middle aged País/Região como assunto: Mexico Idioma: En Revista: Clin Ther Ano de publicação: 2012 Tipo de documento: Article País de afiliação: México

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Piperazinas / Sulfonas / Vasodilatadores / Medicamentos Genéricos Tipo de estudo: Clinical_trials / Prognostic_studies Limite: Adolescent / Adult / Humans / Male / Middle aged País/Região como assunto: Mexico Idioma: En Revista: Clin Ther Ano de publicação: 2012 Tipo de documento: Article País de afiliação: México