Your browser doesn't support javascript.
loading
Aortic valve morphology is associated with outcomes following balloon valvuloplasty for congenital aortic stenosis.
Maskatia, Shiraz A; Justino, Henri; Ing, Frank F; Crystal, Matthew A; Mattamal, Raphael J; Petit, Christopher J.
Afiliação
  • Maskatia SA; Department of Pediatrics, Section of Pediatric Cardiology, Baylor College of Medicine, Texas Children's Hospital, Houston, Texas, USA. samaskat@texaschildrenshospital.org
Catheter Cardiovasc Interv ; 81(1): 90-5, 2013 Jan 01.
Article em En | MEDLINE | ID: mdl-23044747
ABSTRACT

OBJECTIVES:

Evaluate the incidence of various morphologic types of congenital AS, and the association between valve morphology and long-term outcomes, including repeat BAV, AVR, and death/transplant.

BACKGROUND:

Reports on long-term outcomes have low agreement on the influence of morphologic type.

METHODS:

We queried our institutional database and hospital billing records to identify all patients who underwent balloon aortic valvuloplasty (BAV) from 1992 through 2009. We excluded cases where morphology was not clear based on the description in the pre-BAV echocardiogram report and patients who underwent single ventricle palliation. The primary outcome of the study was the occurrence of any of the following events repeat valvuloplasty, AVR, heart transplant, or death.

RESULTS:

There were 147 patients in our study cohort. The most common morphology was functionally bicuspid (n = 92, 63%), followed by functionally unicuspid (n = 20, 14%), dysplastic (n = 16, 11%), true bicuspid (n = 13, 9%), and true unicuspid (n = 6, 4%). The primary endpoint was less likely to occur in patients with functionally bicuspid valves (P < 0.01) and patients with true bicuspid valves (P = 0.03), whereas it was more likely to occur in patients with functionally unicuspid valves (P = 0.02) and patients with true unicuspid valves (P = 0.05). Multivariate Cox regression analysis demonstrated that valve type other than functionally bicuspid was associated with diminished freedom from repeat intervention, death or transplant (HR 3.3, CI 1.2 - 8.6, P = 0.02).

CONCLUSIONS:

In our cohort, patients with functionally bicuspid aortic valves, the most common type, had improved outcomes as compared with all other morphologic types.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Insuficiência da Valva Aórtica / Estenose da Valva Aórtica / Valvuloplastia com Balão / Doenças das Valvas Cardíacas Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Child, preschool / Female / Humans / Infant / Male / Newborn Idioma: En Revista: Catheter Cardiovasc Interv Assunto da revista: CARDIOLOGIA Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Insuficiência da Valva Aórtica / Estenose da Valva Aórtica / Valvuloplastia com Balão / Doenças das Valvas Cardíacas Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Child, preschool / Female / Humans / Infant / Male / Newborn Idioma: En Revista: Catheter Cardiovasc Interv Assunto da revista: CARDIOLOGIA Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Estados Unidos